TomoDirect has been reported to have some advantages over TomoHelical in delivering total body irradiation (TBI). This study aimed to investigate the relationships between the number of ports and the dose evaluation indices in low‐dose TBI in TomoDirect mode using 2–12 ports and to compare these data with those for the TomoHelical mode in a simulation study. Thirteen patients underwent low‐dose TBI in TomoHelical mode from June 2015 to June 2016. We used the same computed tomography data sets for these patients to create new treatment plans for upper‐body parts using TomoDirect mode with 2–12 beam angles as well as TomoHelical mode. The prescription was 4 Gy in two equal fractions. For the TomoDirect data, we generated plans with 2–12 ports with approximately equally spaced angles; the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.500, respectively. For the TomoHelical plans, the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.397, respectively. D2, D98, D50, and the homogeneity index (HI) were evaluated to compare TomoDirect plans having 2–12 ports with the TomoHelical plan. Using TomoDirect plans, D2 with four ports or fewer, D98 with 10 ports or fewer, D50 with four ports or fewer and HI with five ports or fewer showed statistically significantly worse results than the TomoHelical plan. With the TomoDirect plans, D2 with seven ports or more, D50 with eight ports or more, and HI with eight ports or more showed statistically significant improvement compared with the TomoHelical plan. All of the dose evaluation indices of the TomoDirect plans showed a tendency to improve as the number of ports increased. TomoDirect plans showed statistically significant improvement of D2, D50, and HI compared with the TomoHelical plan. Therefore, we conclude that TomoDirect can provide better dose distribution in low‐dose TBI with TomoTherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.