Purpose To examine the diagnostic performance of high-spatial-resolution (HSR) CT with 0.25-mm section thickness for evaluating renal artery in-stent restenosis. Materials and Methods A 0.05-mm wire phantom and vessel phantoms with renal stents with in-stent stenotic sections of varying diameters were scanned with both an HSR CT scanner equipped with 160-section multi-detector rows (0.25-mm section thickness) and a conventional CT scanner. The wire phantom was used to analyze modulation transfer function (MTF). With the vessel phantoms, the error rates were calculated as the absolute difference between the measured diameters and true diameters divided by the true diameters at the narrowing sections. For qualitative evaluation, overall image quality and diagnostic accuracy for evaluating stenosis in three stages were assessed by two radiologists. Statistical analyses included the paired t test, Wilcoxon signed-rank test, and McNemar test. Results HSR CT achieved 24.3 line pairs per centimeter ± 0.5 (standard deviation) and 29.1 line pairs per centimeter ± 0.4 at 10% and 2% MTF, respectively; and conventional CT was 12.5 line pairs per centimeter ± 0.1 and 14.3 line pairs per centimeter ± 0.1 at 10% and 2% MTF, respectively. The mean error rate of the measured diameter at HSR CT (8.0% ± 5.8) was significantly lower than that at at conventional CT (16.9% ± 9.3; P < .001). Image quality at HSR CT was significantly better than that at conventional CT (P < .001), but HSR CT was not significantly superior to conventional CT in terms of diagnostic accuracy. Conclusion Compared with conventional CT, high-spatial-resolution CT achieved spatial resolutions of up to 29 line pairs per centimeter at 2% modulation transfer function and yielded improved measurement accuracy for the evaluation of in-stent restenosis in a phantom study of renal artery stents. Published under a CC BY 4.0 license.
The purpose of this study is to investigate how streak artifacts on computed tomography (CT) images vary with reduction in radiation doses by assessing the quantitative relationship between the streak artifacts and milliampere-time product (mA s) values. A commercially available chest phantom was used to measure the streak artifacts on the CT images obtained using a 4- and 16-multidetector-row helical CT scanners with various mA s values at a constant tube voltage of 120 kVp. The cardiac slice image was employed as a target image for evaluating the streak artifacts on the CT image. Eighty parallel line segments with a length of 20 pixels were placed perpendicular to numerous streak artifacts on the cardiac slice image, and the largest difference between adjacent CT values in each of the 80 CT-value profiles of these line segments was employed as a feature variable of streak artifacts; these feature variables have been analyzed by the extreme value theory. The largest difference between adjacent CT values in each CT-value profile can be statistically modeled by a Gumbel distribution. Further, the maximum level of streak artifacts on CT images that will be tolerated for clinical use and low-dose CT screening examination was expected to be estimated using the location parameter in the Gumbel distribution.
The abundance of left atrial EAT independently predicted early recurrence after AF ablation; on the contrary, it did not have an impact on late recurrence. Left atrial EAT may have a pro-arrhythmic influence, especially in the early post-ablation phase.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.