OBJECTIVES:
Our aim is to compare the efficacy and safety of high-flow nasal cannula (HFNC) against those of nasal continuous positive airway pressure (NCPAP) or nasal intermittent positive-pressure ventilation (NIPPV) after extubation in preterm infants.
METHODS:
This prospective, randomized, noninferiority trial was conducted in 6 tertiary NICUs. Infants born at <34 weeks who needed noninvasive ventilation after extubation were enrolled. We randomly assigned infants to an HFNC group when HFNC was used or to an NCPAP/NIPPV group when NCPAP or NIPPV was used. The primary outcome was treatment failure within 7 days after extubation. We then examined clinical aspects of treatment failure with HFNC use.
RESULTS:
In total, 176 and 196 infants were assigned to the HFNC and NCPAP/NIPPV groups, respectively. The HFNC group showed a significantly higher rate of treatment failure than that of the NCPAP/NIPPV group, with treatment failure occurring in 54 infants (31%) compared with 31 infants (16%) in the NCPAP/NIPPV group (risk difference, 14.9 percentage points; 95% confidence interval, 6.2–23.2). Histologic chorioamnionitis (P = .02), treated patent ductus arteriosus (P = .001), and corrected gestational age at the start of treatment (P = .007) were factors independently related to treatment failure with HFNC use.
CONCLUSIONS:
We found HFNC revealed a significantly higher rate of treatment failure than NCPAP or NIPPV after extubation in preterm infants. The independent factors associated with treatment failure with HFNC use were histologic chorioamnionitis, treated patent ductus arteriosus, and a younger corrected gestational age at the start of treatment.
Bach1 newborn mice were well-recovered from hyperoxia-induced lung injury. This effect is likely achieved by the antioxidant/anti-inflammatory activity of HO-1 or by the transient overexpression of proinflammatory cytokines.
High-flow nasal cannula is a new modality of respiratory support and is increasing in popularity despite the lack of supporting evidence. We investigated the prevalence of its use in tertiary neonatal units in Japan. A paper-based survey was conducted. The response rate was 83%. High-flow nasal cannula was used in 46/80 units (58%), of which 96% used the high-flow nasal cannula without guidelines. It was used for several indications, including weaning off nasal continuous positive airway pressure and post-extubation respiratory support. The main perceived benefits of the cannula included better access to the neonate and reduced risk of nasal trauma. This survey found that high-flow nasal cannula is used without clear criteria and that clinical practice varies across neonatal units in Japan. Its use in neonates needs to be urgently evaluated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.