A 42-year-old Japanese woman developed an eczematous skin rash around the catheter exit during continuous ambulatory peritoneal dialysis (CAPD). The same kind of lesion developed around a Scribner shunt exit. Skin biopsy indicated chronic eosinophilic dermatitis. In the patch test she developed an allergic reaction to the silicone rubber catheter but not to the antiseptic solutions. Based on these findings, we concluded that her “eczematous” rash represented an allergic response to silicone rubber in the peritoneal catheter. To this date the literature contains no reports of such a catheter complication in CAPD. Catheter complications in patients on CAPD are mainly infection and mechanical dysfunction such as poor drainage or leaks (I, 2). Eosinophilic dermatitis around the catheter exit caused by the silicone rubber is extremely uncommon (3). As yet no reports have been published concerning this rare catheter complication.
Sarcoidosis is a multisystem disease of unknown etiology, developing granulomas in any tissues and organs. Approximately 25% of sarcoidosis patients have cutaneous involvement with various clinical manifestations, which are categorized into specific or nonspecific diseases based on the histopathology; the former represents the typical sarcoid granulomas. Subcutaneous sarcoidosis is one of the specific skin lesions and often affects extremities, to a much lesser extent with other anatomical sites. Herein, we report the case of an 82-year-old Japanese man with subcutaneous sarcoidosis whose skin nodules exclusively overlay the lines of superficial veins on the forearms. This rare clinical presentation was discussed with the literature reported thus far to access the underlying disease pathophysiology from the viewpoint of tropic response to the venous system in systemic sarcoidosis.
Necrotising fasciitis is a rare but serious bacterial infection characterised by progressive necrosis of the skin, s.c. tissue and fasciae. 2 In immunocompromised patients, necrotising fasciitis can occur even after minor breaches of the skin. In our patient, her past medical history included diabetes mellitus. High doses of oral prednisolone were administered. The patient developed severe skin lesions which became colonised with MSSA. Although necrotising fasciitis represents an unusual complication of bullous pemphigoid, 1 the insertion and placement of the catheter may have caused the onset of the disease.I.v. immunoglobulin is currently used to treat a wide variety of autoimmune and inflammatory diseases. 3 It provides a beneficial therapeutic outcome for patients with bullous pemphigoid who are resistant to steroid therapy. 4 I.v. immunoglobulin has also been evaluated for the adjunct treatment of refractory and difficult-to-treat chronic infections. 5 Taken together, i.v. immunoglobulin therapy is a good therapeutic option to treat bullous pemphigoid complicated by severe bacterial infections, as in our patient.
Due to their high energy density, lithium-ion rechargeable batteries have been increasingly used in various electronic devices as useful and efficient electric energy storages. On the other hand, it is well known that some critical states such as over-charge or over-discharge of a lithium-ion battery may lead to dangerous situations and may accelerate the aging of its capacity. it is thus necessary to accurately estimate the State-of-Charge (SOC) of the the batteries for safe and long lasting operations[1]. Recently, some SOC estimation methods employing the extended Kalman filtering (EKF) technique have been reported based on the state-space representation of an equivalent circuit model (Figure 1) [2]-[5]. One of the main difficulties in these model-based methods is that the physical parameters of the equivalent circuit change in time depending on the SOC and temperature of the battery. A typical approach to cope with this is to model a priorithe SOC- and temperature-dependences of these parameters from the measurements obtained from AC impedance experiments [4],[5]. This approach requires a lot of time to acquire the experimental data. In this work, we take a different approach from the above previous works. We present a method for simultaneous estimation of the SOC and the equivalent circuit parameters by combining the EKF and the recursive least-squares (RLS) identification algorithm. The schematic diagram of the proposed method is illustrated in Figure 2. The advantages of the proposed method are as follows. The equivalent circuit parameters can be accurately estimated on-line by the RLS in various operating conditions without prior information nor preliminary experiments. The parameter estimation part of the proposed method is indenpendent from the nonlinear characteristics of the SOC dependence of the open circuit voltage (OCV). The effectiveness of the proposed method is verified through a discharge experiment of a LiFeO4 battery with the nominal capacity 48.5Ah and the maximum voltage 3.5V. The SOC estimation of a LiFeO4 battery is difficult because its SOC-OCV characteristic curve is almost flat in the middle range of the SOC. The terminal voltage and current are measured at the sampling period 1sec. The input current is a quasi-random sequence whose power is concentrated in the frequency bands around 0.07Hz and 0.03Hz (Figure 3). The RMS values of the SOC estimation errors are shown in Table1. It is seen from the table that the proposed method improves the estimation accuracy than the previous method due to Oya et al.[5]. Table1 RMS errors of SOC estimates Proposed method 1.069[%] Previous method[3] 1.998[%] The accuracy of the parameter estimates is assessed in terms of the Cole-Cole plots in Figure 4, where the x- and o-indications respectively denote the points at the Nyquist frequency 0.5Hz and the lowest frequency 0.08Hz measurable by our impedance analyzer. For both SOC=20% and 50%, in the operating frequency band lower around 0.08Hz, the estimates by the RLS (blue) are much closer to the measured values (red) than the previous method due to Oya et al.[5] (green). This is not the case for SOC=80%, which is because of the transient behavior of the RLS algorithm during the initial period of the discharge experiment. From the above experimental results, we conclude the following as the main finding of this work. The RLS algorithm can provide a good estimation of the equivalent circuit model in the sense that the obtained parameter estimates well describe the battery behavior in the operating frequencies rather than all frequencies, and this fact accounts for the SOC estimation accuracy of the proposed combined RLS-EKF method. It may also be noted that the frequency domain analysis presented in this paper will be helpful in assessment or validations of various model-based SOC estimation algorithms. References: [1] P. Weicker: A System Approach to Lithium-ion Battery Management, Artech House, 2014. [2] G.L. Plett: Extended Kalman filtering for battery management systems of LiPB based HEV battery packs: Part 2. Modeling and identification, Journal of Power Sources, 134, pp. 262-276, 2004. [3] A. Baba and S. Adachi: State of charge estimation of lithium-ion battery using Kalman filters, Proc. of 2012 IEEE Int. Conf. on Control Applications (CCA2012), pp. 409-414, 2012. [4] R. Ishizaki, L. Lin, N. Kawarabayashi, and M. Fukui: An SOC estimation system for lithium-ion batteries considering thermal characteristics, Proc. of 19th Workshop on Synthesis and System Integration of Mixed Information Technologies (SASIMI2015), pp. 16-21, 2015. [5] M.Oya, K.Takaba, L.Lin, R.Ishizaki, N.Kawarabayashi and M.Fukui: Accurate SoC estimation of lithium-ion batteries based on parameter-dependent state-space model, Proc. 15th Int. Symp. on Communications and Information Technologies (ISCIT2015), pp.37-40, 2015. Figure 1
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.