Nowadays, footwear serves an essential role in improving athletic performance and decreasing the risk of unexpected injuries in sports games. Finite element (FE) modeling is a powerful tool to reveal the biomechanical interactions between foot and footwear, and establishing a coupled foot-shoe model is the prerequisite. The purpose of this pilot study was to develop and validate a 3D FE coupled model of the foot and sports shoe complex during balanced standing. All major foot and shoe structures were constructed based on the participant’s medical CT images, and 3D gait analysis was conducted to define the loading and boundary conditions. Sensitivity analysis was applied to determine the optimum material property for shoe sole. Both the plantar and shoe sole areas were further divided into four regions for model validation, and the Bland–Altman method was used for consistency analysis between methods. The simulated peak plantar and sole pressure distribution showed good consistency with experimental pressure data, and the prediction errors were all less than 10% during balanced standing with only two exceptions (medial and lateral forefoot regions). Meanwhile, the Bland–Altman analysis demonstrated a good agreement between the two approaches. The sensitivity analysis suggested that shoe sole with Young’s modulus of 2.739 MPa presented the greatest consistency with the measured data in our scenario. The established model could be used for investing the complex biomechanical interactions between the foot and sports shoe and optimizing footwear design, after it has been fully validated in the subsequent works under different conditions.
Background: To explore the biomechanical characteristics of 2 posterior bilateral pedicle screw fixation methods using finite element analysis.Methods: A normal L3-5 finite element model was established. Based on the verification of its effectiveness, 2 different posterior internal fixation methods were simulated: bilateral pedicle screws (model A) were placed in the L3 and L5 vertebral bodies, and bilateral pedicle screws (model B) were placed in the L3, L4, and L5 vertebral bodies. The stability and stress differences of intervertebral discs, endplates, screws, and rods between models were compared.Results: Compared with the normal model, the maximum stress of the range of motion, intervertebral disc, and endplate of the 2 models decreased significantly. Under the 6 working conditions, the 2 internal fixation methods have similar effects on the stress of the endplate and intervertebral disc, but the maximum stress of the screws and rods of model B is smaller than that of model A.Conclusions: Based on these results, it was found that bilateral pedicle screw fixation in 2 vertebrae L3 and L5 can achieve similar stability as bilateral pedicle screw fixation in 3 vertebrae L3, L4, and L5. However, the maximum stress of the screw and rod in model B is less than that in model A, so this internal fixation method can effectively reduce the risk of fracture. The 3-dimensional finite element model established in this study is in line with the biomechanical characteristics of the spine and can be used for further studies on spinal column biomechanics. This information can serve as a reference for clinicians for surgical selection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.