Purpose: To investigate the retinal light hazard during macular surgery using a digital three-dimensional visualization system (3D) and a conventional microscope (CM).Design: Experimental study and retrospective evaluation of a case-control study.Subjects: A total of 20 and 10 patients who underwent pars plana vitrectomy for epiretinal membrane using 3D and CM, respectively.Methods: Spectral irradiances of endoilluminators were measured for representative settings used during core vitrectomy and macular manipulations with 3D and CM. From the medical record of the patients, time needed for core vitrectomy and macular manipulations was extracted. The total retinal light hazard index and the macular hazard index were calculated based on the spectral irradiances weighted by the standard functions. Total retinal light hazard index, macular hazard index, and the number of cases that exceeded the maximum permissible radiant power exposure were compared between the two groups.Results: The spectral irradiance were 1.6 and 3.9 mW/cm 2 for core vitrectomy and 3.4 and 8.1 mW/cm 2 for macular manipulations using typical settings for 3D and CM groups, respectively. The total retinal light hazard index ranged from 4.31 kJ/m 2 to 17.37 kJ/m 2 for 3D and 11.09 kJ/m 2 to 27.70 kJ/m 2 for CM groups, respectively, whereas the macular hazard index ranged from 2.93 kJ/m 2 to 14.58 kJ/m 2 for 3D and from 6.84 kJ/m 2 to 23.55 kJ/m 2 for CM, respectively (P , 0.001). One (5%) and 6 (60%) pars plana vitrectomy cases exceeded the threshold limits with 3D and CM groups, respectively (P , 0.05, chi-square test).Conclusion: The 3D digitally assisted visualization system offers significantly safer macular surgery compared with the CM, considering the potential retinal hazard.
Purpose: This study aims to investigate the postoperative refractive outcomes in eyes that underwent the flanged intrascleral intraocular lens (IOL) fixation combined with vitrectomy with or without gas/air tamponade. Methods: The eyes were divided into two groups (Group A; eyes that underwent flanged intrascleral IOL fixation with gas/air tamponade, and Group B; eyes that underwent flanged intrascleral IOL fixation without gas/air tamponade). The predicted spherical equivalent (SE) refraction values were calculated using the Sander–Retzlaff–Kraff Theoretical formula. Then, the prediction error was calculated by subtracting the predicted SE refraction from the postoperative objective SE refraction and the absolute prediction error was calculated as the absolute value of the prediction error for each eye. Results: A total of 68 eyes were included in the current study. There was a significant correlation between the predicted and postoperative SE refraction in both groups (Group A, r = 0.968, P < 0.0001, Group B, r = 0.943, P < 0.0001, linear regression analysis). The prediction error demonstrated a mild myopic shift after the flanged intrascleral IOL fixation in both groups (Group A, −0.40 ± 0.96 diopter, Group B, −0.59 ± 0.95 diopter). There was no significant difference in prediction error and absolute prediction error between the two groups (P = 0.44, P = 0.70, Wilcoxon rank sum test). Conclusion: The postoperative SE refraction after flanged intrascleral IOL fixation was not influenced by gas/air tamponade.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.