Rationale: Brolucizumab is a novel anti-vascular endothelial growth factor agent with clinical trials demonstrating excellent efficacy for neovascular age-related macular degeneration (AMD) in both visual and anatomic outcomes. However, there is concern of intraocular inflammation (IOI), and we propose concurrent subtenon triamcinolone acetonide (STTA) to prevent IOI. Patient concern: A 73-year-old man was treated with aflibercept for neovascular AMD in his right eye. Despite 11 months of monthly intravitreal aflibercept injections, optical coherence tomography demonstrated persistent exudation. Ten days following his second brolucizumab injection, the patient presented with decreased vision due to vitritis in his right eye Diagnosis: Brolucizumab-related IOI in neovascular AMD refractory to aflibercept. Interventions: A combination therapy involving of intravitreal brolucizumab and STTA Outcomes: The anti-vascular endothelial growth factor inhibitor was changed back to aflibercept; however, exudation persisted. Therefore, a combination therapy involving STTA (5 mg/0.5 mL) and intravitreal injection of brolucizumab (6.0 mg/0.05 mL) was performed to treat the exudation and as prophylaxis to recurrent IOI. Combination therapy achieved no recurrent IOI and resolution of exudation with 8-week treatment intervals. Lessons: This case might indicate that STTA is not only an optimal treatment option for brolucizumab-related IOI but also a preventive agent for this condition.
Purpose: To investigate how many tests need to be performed to adequately assess intraocular pressure (IOP) diurnal change using a self-measuring rebound tonometer among glaucoma patients. Subjects and Methods: Adult patients with primary open-angle glaucoma were included. IOP was measured in the morning (6 AM to 9 AM), afternoon (12 PM to 3 PM), and at night (6 PM to 9 PM) for seven consecutive days. Twenty-four (7 males and 17 females, mean age 59.5 ± 11.0 years) patients who successfully measured IOP at least three times per day during the correct time periods for four days were subjected to analysis. Results: The IOP rhythm was significantly greater on the first day of measurement (6.6 ± 3.6 mmHg) than that averaged during subsequent days (4.4 ± 2.2 mmHg). The time of the highest and lowest IOP measurements on the first day of IOP measurement and during the entire measurement period coincided in 72.9% and 64.6% of cases, respectively. The concordance rate of the highest IOP time between the whole measurement period and each measurement day was less than 60%. Conclusion: The diurnal IOP rhythm measured by the patients themselves was not consistent, and multiple days of measurements may be necessary to correctly assess diurnal IOP rhythm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.