This paper describes a methodology and specifics for technical studies on fault-induced delayed voltage recovery (FIDVR) mitigation to ensure power system reliability. Optimal locations of the dynamic volts-ampere-reactive (VAR) sources are determined for addressing the FIDVR issues in the voltage stability analysis and assessment methodology. We propose a voltage stability analysis method for planning dynamic VAR sources for bettering electric power transmission systems under contingency conditions. A time-domain dynamic simulation is performed to assess short-term voltage stability. While conducting dynamic simulations, sensitivity analysis is performed to assess the need for dynamic VAR sources. This study focuses on a reactive power compensation strategy to determine system voltage recovery performance by optimal flexible alternating current transmission system (FACTS) placement in a metropolitan region. The objective of this study is to determine the optimal installation of dynamic VAR sources while satisfying the requirements of voltage stability margin and transient voltage dip under a set of criteria. New insights are presented on the effect of FACTS controls on the reactive power compensation, which supports voltage recovery. The main features of the proposed method are (i) the development based on a load model for FIDVR, (ii) the use of sensitivity analysis of the network to the variations of the IM load, (iii) the establishment of the control function and compensation strategy to maintain the voltage of system within criteria limits, and (iv) the use of the sensitivity analysis based on branch parameterization for unsolvable cases. Case studies on the Korean power system validated the performance of the proposed strategy, showing that it effectively installed FACTS under contingency scenarios.
This study aims to develop a real-time assessing methodology for a power systems voltage stability. The proposed algorithm is based on the Thévenin equivalent (TE) impedance estimation method, which applies the phasor measurement unit technology practically. To present an accurate analysis of the real-time situations of a power system, the developed voltage stability index can be used as useful information for system operators to establish appropriate countermeasures. Moreover, by considering the results of voltage stability margin calculation within the Korean power system, the effect of voltage stability on the dynamic behavior of the system is presented. Furthermore, to increase the accuracy, load model parameter estimation is introduced in this algorithm. The load model might be used for calculating the stability margin more accurately. The power-voltage curve is drawn in theory using the TE voltages and impedances. To validate the case study of the proposed method, simulations were executed using the Matlab software. The simulations demonstrated the effectiveness of the proposed method and detected voltage stability/instability under severe contingency scenarios.
This study develops an analytical method for assessing the voltage stability margins of a decentralized load shedding scheme; it then examines the challenges related to the existing load shedding scheme. It also presents a practical application for implementing the proposed method, based on the synchrophasor measurement technology in modern power grid operations. By applying the concept of a continuously-computed voltage stability margin index to the configuration of the Thévenin equivalent system, the maximum transfer power could be used as an index to monitor the voltage instability phenomenon and thus determine the required load shedding amount. Thus, the calculated voltage stability margin might be a useful index for system operators in the critical decision-making process of load shedding. Dynamic simulations are performed on real Korean power systems as case studies. Simulation results, when comparing the existing and proposed methods, showed that there was a considerable reduction in the amount of load shedding in the voltage instability scenario. This indicates that the synchrophasor measurement technology has a considerable effect on the proposed load shedding method. The simulation results have validated the performance of the proposed method.
This paper aims to develop a multi-phase under voltage load shedding (MUVLS) strategy that effectively sheds the load to mitigate delayed voltage recovery (DVR). The major cause of the DVR phenomenon is related to the dynamic characteristics of induction motor (IM) loads. The deaccelerating and stalling of the IM load during disturbances is the main driving force of short-term voltage instability, resulting in an amount of reactive power consumption and excessive current draw. With the economic efficiency of energy use, the proportion of IM loads is gradually increasing, and this trend might deteriorate system stability. This paper focuses on the impact of IM loads in the Korean power system and analyzes the parameter sensitivity of IM loads and the proportion of appropriate IM loads. The proposed procedure for under voltage load shedding (UVLS) applies voltage stability criteria to decide the most efficient load shedding scheme. The determined MUVLS scheme can offer new and more effective remedial actions to maintain voltage stability, considering the characteristics of IM loads. Case studies on the Korean power system have validated the performance of the proposed MUVLS scheme under severe contingency scenarios, showing that the proposed strategy effectively mitigates DVR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.