Purpose: To report a case of spontaneous closure of simultaneous full-thickness macular hole.Methods: Case report and literature review.Results: A 67-year-old woman with small-diameter simultaneous macular holes was observed for a period of 5 months, and progression was documented with spectral-domain optical coherence tomography. Closure of right full-thickness macular hole was evidenced by 1 month and left full-thickness macular hole by 5 months.
Conclusion:This case demonstrates possible spontaneous resolution of a condition that is usually treated surgically. A period of observation with serial imaging studies may be advised in cases of small macular holes.
iOCT provides anatomical information during MH surgery that may impact surgical decision-making by allowing a real-time evaluation of structures. iOCT with preservative-free triamcinolone acetonide enhanced ILM visualization. Its use is superior to iOCT alone for the identification of vitreomacular interface structures. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:e105-e111.].
Purpose:
To evaluate the safety and efficacy of 80-μm flap femtosecond laser–assisted LASIK and the early clinical and refractive outcomes in the correction of myopia and myopic astigmatism.
Setting:
Private practice, outpatient.
Design:
Prospective study.
Methods:
Patients who underwent femtosecond-assisted LASIK between February and April 2018 were included. Inclusion criteria were myopia from −1.00 to −8.00 diopters (D) and astigmatism up to −3.00 D and no previous surgeries. All patients were tested preoperatively and on day 1 and month 3 for uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), intraocular pressure (IOP), slitlamp and dilated fundus examination, Schirmer I test with anesthesia, and ocular surface disease index questionnaire. The FEMTO LDV Z8 was used for flap construction and the Wavelight Allegretto 400 excimer for refractive treatment. Flap thickness was measured at week 1 with anterior segment optical coherence tomography (AS-OCT).
Results:
Eighty-two eyes were included. Logarithm of the minimum angle of resolution UDVA was 1.28 ± 0.53 preoperatively, 0.02 ± 0.05 at day 1, and 0.14 ± 0.127 at month 3. There was no loss of CDVA lines. The mean flap thickness measured at 1 week with AS-OCT was 73 ± 6.7 µm.
Conclusions:
The use of ultrathin flaps, just below Bowman's layer, with the Ziemer LDV Z8 femtosecond laser was possible, safe, reliable, and reproducible. Eighty-micron flaps allowed for excellent vision on 1 day post-LASIK and might be a good alternative to maintain an appropriate percentage of tissue altered, especially when attempting greater corrections or larger treatment zones.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.