Cytokines are signaling molecules secreted and sensed by immune and other cell types, enabling dynamic intercellular communication. Although a vast amount of data on these interactions exists, this information is not compiled, integrated or easily searchable. Here we report immuneXpresso, a text-mining engine that structures and standardizes knowledge of immune intercellular communication. We applied immuneXpresso to PubMed to identify relationships between 340 cell types and 140 cytokines across thousands of diseases. The method is able to distinguish between incoming and outgoing interactions, and it includes the effect of the interaction and the cellular function involved. These factors are assigned a confidence score and linked to the disease. By leveraging the breadth of this network, we predicted and experimentally verified previously unappreciated cell-cytokine interactions. We also built a global immune-centric view of diseases and used it to predict cytokine-disease associations. This standardized knowledgebase (http://www.immunexpresso.org) opens up new directions for interpretation of immune data and model-driven systems immunology.
Background Privacy restrictions limit access to protected patient-derived health information for research purposes. Consequently, data anonymization is required to allow researchers data access for initial analysis before granting institutional review board approval. A system installed and activated at our institution enables synthetic data generation that mimics data from real electronic medical records, wherein only fictitious patients are listed. Objective This paper aimed to validate the results obtained when analyzing synthetic structured data for medical research. A comprehensive validation process concerning meaningful clinical questions and various types of data was conducted to assess the accuracy and precision of statistical estimates derived from synthetic patient data. Methods A cross-hospital project was conducted to validate results obtained from synthetic data produced for five contemporary studies on various topics. For each study, results derived from synthetic data were compared with those based on real data. In addition, repeatedly generated synthetic datasets were used to estimate the bias and stability of results obtained from synthetic data. Results This study demonstrated that results derived from synthetic data were predictive of results from real data. When the number of patients was large relative to the number of variables used, highly accurate and strongly consistent results were observed between synthetic and real data. For studies based on smaller populations that accounted for confounders and modifiers by multivariate models, predictions were of moderate accuracy, yet clear trends were correctly observed. Conclusions The use of synthetic structured data provides a close estimate to real data results and is thus a powerful tool in shaping research hypotheses and accessing estimated analyses, without risking patient privacy. Synthetic data enable broad access to data (eg, for out-of-organization researchers), and rapid, safe, and repeatable analysis of data in hospitals or other health organizations where patient privacy is a primary value.
This study characterizes, for the first time, contacts to CdZnTe radiation detectors by measuring the dark noise spectra as a function of the applied bias. The noise currents are correlated with the dc dark current-voltage characteristics of CdZnTe x-ray and gamma-ray detectors. In order to identify and separate the role of the contacts in the overall performance, the measured noise phenomena is correlated with detector configuration and contact design as well as the growth method of the CdZnTe crystals, contact technology, and passivation. Several contact technologies (electroless gold, and a number of evaporated metallic contacts including gold, indium, zinc, titanium, aluminum, and platinum contacts) are compared. Contacts to CdZnTe crystals grown by high pressure Bridgman are compared with contacts to CdZnTe crystals grown by modified Bridgman. Contacts of resistive detectors as well as of Schottky detectors are reported. Large area symmetric contacts are compared with small area pixelized contacts. The role of the metallization used for contacts, the role of surface effects and passivation, and the role of contact design are discussed.
Background The overall risk of postcontrast acute kidney injury (PC-AKI) after computerized tomography (CT) is negligible, likely because of the small volume of injected iodinated contrast media required. However, the safety of contrast media–enhanced CT in patients with advanced renal functional impairment, an established major risk factor for PC-AKI, is unknown. Materials and Methods This is a retrospective study using large data analysis of hospitalized patients at a single center. Adults undergoing CT or magnetic resonance imaging were included in the study and were stratified by estimated glomerular filtration rate (eGFR) (≤30 or >30 mL/min/1.73 m2) and by either contrast-enhanced or nonenhanced imaging. Only patients with serial determination of creatinine before and after imaging were included. Demographic, clinical, and laboratory data between groups were analyzed and compared using univariate analysis, propensity score matching, and multivariate logistic regression analysis. Results A total of 22,319 imaging studies were included. Patients with an eGFR of 30 mL/min/1.73 m2 or lower undergoing contrast-enhanced CT (n = 403) had an increased risk to develop PC-AKI than did similar patients undergoing enhanced or nonenhanced magnetic resonance imaging (n = 96) or nonenhanced CT (n = 1576) or patients undergoing contrast-enhanced CT with a preprocedural eGFR higher than 30 mL/min/1.73 m2 (n = 9173). These findings remained robust after propensity matching for demographic, procedural, and clinical parameters. Multivariate regression analysis of all patients undergoing CT with preimaging eGFR of 30 mL/min or lower (n = 1979) revealed that iodine-based contrast enhancement increased the likelihood of post-CT AKI by 51% (confidence interval, 1.23–2.05). Conclusion Although radiocontrast-enhanced CT is considered safe in most hospitalized patients and in ambulatory settings, the risk of PC-AKI remains significant among inpatients with substantial preimaging renal functional impairment. Caution is warranted using iodine-based enhanced CT in hospitalized patients with an eGFR of 30 mL/min/1.73 m2 or lower.
IntroductionAcute kidney injury associated with near-drowning (ND-AKI) has rarely been reported and its incidence among survivors is unknown. A patient with AKI and urine biomarkers indicating tubular injury led us to assess the occurrence and clinical characteristics of ND-AKI and to evaluate possible causative mechanisms.MethodsWe evaluated medical records of patients rescued from near-drowning in the Mediterranean Sea and treated in a tertiary-level medical center during 2000 to 2017.ResultsNinety-five patients with the diagnosis of near-drowning in seawater were treated. Forty-two of these patients (43%) developed ND-AKI and 17 (18%) were classified as AKI Kidney Disease: Improving Global Outcomes stages 2 to 3. ND-AKI was associated with the need for resuscitation and mechanical ventilation, with the calculated seawater volume ingestion (extrapolated from rising plasma sodium) and with the degree of acidemia, lactemia, and ventilatory failure. This series and 28 additional published cases of ND-AKI in the literature showed an overall male predisposition.ConclusionAKI is a common complication of near-drowning and is associated with increased in-hospital mortality. Data analysis suggests a predominant role of hypoxic tubular injury due to systemic hypoxemia in ND-AKI, combined with intense sympathetic activity (reflected by tachyarrhythmias, hyperglycemia, and relative hypokalemia) and increased oxygen expenditure for intensified distal tubular sodium transport. Androgen-related reduced renal vasodilatory capacity may explain male gender predominance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.