No abstract
Graphene/hBN heterostructures can be considered as one of the basic building blocks for the next- generation optoelectronics mostly owing to the record-high electron mobilities. However, currently the studies of optical properties of graphene are limited to the standard substrates (SiO2/Si, glass, quartz) despite the growing interest in graphene/hBN heterostructures. This can be attributed to a challenging task of the determination of hBN’s strongly anisotropic dielectric tensor in the total optical response. In this study, we overcome this issue through imaging spectroscopic ellipsometry utilizing simultaneous analysis of hBN’s optical response with and without graphene monolayers. Our technique allowed us to retrieve the optical constants of graphene from graphene/hBN heterostructure in a broad spectral range of 250 - 950 nm. Our results suggest that graphene’s absorption on hBN may exceed the one of graphene on SiO2/Si by about 60%.
Hydrogen can be released during the thermal decomposition of organic materials, therefore, monitoring its level in the working industrial high-voltage transformer oil allows you to identify the development of degenerative processes in advance, because these processes can lead to an accident in the future. In experiments has shown that highly sensitive and small-sized field effect gas sensor based on the metal-insulator-semiconductor structure can be used for measuring of Hydrogen in oil with direct contact of its structure with transformer oil. Given the harsh environmental conditions of hydrogen measurement the field effect capacity type gas sensor were fabricated by using laser micromilling technique for fabrication compact ceramic surface mounting device package and microheater for sustentation working temperature of metal-insulator-semiconductor structure.
Introduction Hydrogen can be released during the thermal decomposition of organic materials; therefore, monitoring its level in the working industrial high-voltage transformer oil allows you to identify the development of degenerative processes in advance, because these processes can lead to an accident in the future. In experiments has shown that highly sensitive and small-sized field effect gas sensor based on the metal-insulator-semiconductor (MIS) structure can be used for measuring of H2 in oil with direct contact of its structure with transformer oil. Hydrogen Diffusion in Transformer Oil Numerical estimates show that with the diffusion coefficient D = 4*10-9 m2/s [1] (at room temperature), the time required for H2 saturation in a transformer oil with 10 cm depth to a level 0,9C0 is more than 1 year. In reality, there are convective flows occurred due to the temperature gradient which are combined with diffusion. Nevertheless, such a large diffusion time must be taken into account when designing the experimental setup and the obtained results interpreting. Field-Effect Gas Sensor A schematic representation of the field-effect gas sensor is shown on Figure 1 and described in work [2]. The measuring H2 concentration with the field-effect gas sensor is as follows. When hydrogen molecules from the external environment interact with the metal electrode, H2 molecules decompose into atoms and diffuse to the metal-insulator interface. It is known that on the surface of palladium hydrogen atoms have a dipole moment. The electric field of dipoles leads to a change in the electric field in the dielectric and in the surface layer of the semiconductor. As a result, the capacitance of the MIS-structure changes, the value of which is fixed by the electronic unit while maintaining a constant bias voltage on the MIS-structure. Results and Conclusions The setup used in experiment (Fig. 2) provides similar to a transformer conditions of H2 diffusion. Both field-effect sensors were preliminarily calibrated for H2 in air (in the concentration range 5-100 ppm) at the sensing element temperatures of 23 and 100°С. The optimal temperature of the sensor structure is 100-150°C. However, in experiments, the main sensor could not be maintained at this temperature due to intense heat exchange with oil. For this reason, its heating element was turned off and equal to the temperature of the oil and was 23°C. The reference sensor was maintained at a temperature of 100°C. Relative humidity above oil was 25%. The experiment was carried out as follows. Through drainage tubes, fixed H2 concentrations in the range from 5 ppm to 100 ppm were fed into the container. After the mixture was supplied, the tubes were blocked and, subsequently, the H2 concentration in the vessel was monitored by sensor (Fig. 2 (3)). To accelerate the process of oil saturation with H2, a mixing device was used, the rotation frequency of which was selected to exclude the formation of air bubbles in the oil. Figure 3 shows the dependence of the response of the sensors (main and reference) on the concentration of H2. Table 1 shows the measurement results. The experiment showed that the temperature of the sensor has a significant effect on the detection time of H2. Immersion of the sensor in oil leads to an increase in the noise level of the signal and a decrease in the sensitivity of the sensor in the low concentrations range. Also, the presence of transformer oil does not change the functional dependence of the sensor capacity on the H2 concentration. The response time to H2 is significantly less than the time of its diffusion in oil, which makes it possible to use the sensor as a sensitive element in the control systems for the level of dissolved H2 in the oil of a working transformer. Acknowledgment This work was funded by the Russian Science Foundation under Grant no 18-79-10230 from 08.08.2018. References [1] Bychkov A.L., Korobeynikov S.M., Ryzhkina A.Y., Determination of the hydrogen diffusion coefficient in transformer oil, Technical Physics. The Russian Journal of Applied Physics. 81 (2011) 106-107. [2] Nikolaev, I.N., Kalinina, L.N., Litvinov, A.V. MIS sensors for hydrogen content measurements in 10 -4 -10 2 volume percent range (2011) Automation and Remote Control, 72 (2), pp. 442-448. Figure 1
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.