Sudden pipe bursts occur in high-pressure water transmission pipelines and water distribution networks. The consequences of these bursts can be very expensive due to the outage time while the burst pipe is repaired, the cost of repair, and damage to surrounding property and infrastructure. As a result, it is advantageous to minimise the detection and location time after the burst occurs.Currently, there is no effective solution for the burst detection and location problem in water distribution systems. The applications in oil and gas pipelines and pipe networks show the advantages of continuous monitoring. A number of techniques are used to determine the location and size of a burst. One of the most promising approaches is fluid transient modelling and analysis. Pressure transient analysis has also been successfully applied for detection and location of existing leaks.A sudden pipe burst creates a negative pressure wave that travels in both directions away from the burst point. The analysis of this wave is the main principle for the techniques presented in this thesis. Experiences from previous research suggest that, to achieve the best performance, single pipelines and pipe networks have to be treated separately. Thus, two different approaches for burst detection and location are presented.When a burst occurs in a pipeline, the burst-induced pressure wave travels in both directions along the pipeline and is reflected at the boundaries. Using a pressure trace measured at one location along the pipeline, the timing of the initial and reflected burst-induced waves determines the location of the burst. The presented continuous monitoring technique uses the modified two-sided cumulative sum (CUSUM) algorithm to detect abrupt changes in the pressure iii data caused by the pipe break. The results from both laboratory and field pipelines are used to verify the proposed method. Different burst and measurement locations are tested. The results are promising for burst detection and location in real systems.In the network case, continuous pressure measurements at two locations are analysed. The burst detection and location algorithm is based on the difference between the arrival times of the burst-induced pressure wave at each measurement point and on the measured wave magnitude. The arrival times are determined automatically in real time. A method for determining optimal measurement locations is also presented. Results from numerical simulations show that the proposed technique has potential as a tool for effective detection and location of bursts in real pipe networks.
The study presents an electric network that allows both increasing the level of electrical safety and eliminating one-phase damage to the electrical network without switching off the consumer's electric energy. The application of the network does not require significant investments. The technical feasibility of implementing an electrical installation with voltage values in the emergency mode on the leading parts, which does not exceed the permissible values for normal mode, is demonstrated. An additional advantage of the proposed technical solution is the immutability of the voltage at the customer's outputs, which allows it to operate normally also in the emergency mode of the electrical installation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.