The sensing of gas components in a mixed gas is required for breath-based health monitoring and diagnosis. In this work, we report the simultaneous detection of mixed-gas components using a sensor consisting of [EMIM][BF 4 ]-based ionic gel with four electrodes made of Au, Pt, Rh, and Cr. The voltage between any given pair of electrodes depends on the gas molecules absorbed in the ionic gel and the elements the electrodes are made of. When the voltage signals between all pairs of electrodes were used, H 2 , NH 3 , and C 2 H 5 OH concentrations were simultaneously estimated by a neural-network-based inference. From molecular dynamics simulations, the origin of the voltage signal was attributed to the catalytically generated adsorbates on the electrodes.
Introduction Ionic Liquids (ILs) are molten salts at room temperature and have both solvent and electrolyte properties. ILs have been actively studied for use in electrochemical gas sensors, thanks to their gas absorption property, electrochemical stability, and low evaporation loss. For example, gas sensors based on the changes in electrical double layer capacitance or in bulk impedance induced by gas dissolution in ionic liquids have been reported [1, 2]. However, there are few reports on the selective recognition of volatile organic compounds such as metabolites in human exhaled air against interfering gases. In this study, we demonstrated selective recognitions of acetone, which is a typical low-molecular-weight metabolic gas in human exhaled air, against hydrogen, which is a metabolite of enterobacteria, by electrochemical impedance measurement using ionic liquids. Method The interdigitated electrodes made of Cr/Pt shown in Fig. 1 were fabricated on a glass substrate. The 3-nm-thick chromium film acting as the adhesion layer was deposited by electron beam evaporation technique, which was followed by the pattern definition and evaporation of 100-nm-thick platinum electrode acting as the main electrical conduction layer. The droplet of 3-μL 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, a kind of ionic liquids, was casted onto the electrodes, which completed the fabrication of a two-terminal electrochemical sensor. The impedance measurements were performed under various atmospheres. The following shows the sequence of atmospheres under which the impedance responses of the fabricated sensors were measured. ⅰ) Dry air (3 min) ⅱ) (case Ⅰ) 25-ppm H2 in dry air (3 min)ⅱ) (case Ⅱ) 25-ppm CH3COCH3 in dry air (3 min) ⅲ) dry air (3 min)In the second process ii), case I or case II was chosen from two target gases; hydrogen and acetone. The gas flow rate was kept constant at 200 sccm. Impedance measurements were performed using an LCR meter (Keysight E4980A) with DC bias of 0.0 V and AC amplitude of 10 mV. The measurement frequency was varied from 300 kHz to 20 Hz. Results Fig. 2 shows the measured sensor response at (a) 200 kHz, (b) 30 Hz, and (c) 350 Hz. The sensor response is defined as impedance change ΔZ re due to target molecules normalized by the impedance in dry air Z re(Air), where Z re represents the real part of the impedance. The equation used to extract the sensor response is shown in Fig. 2. We noticed that the sensor response was strongly dependent on the measured frequency. Z re decreases at 200 kHz in both the CH3COCH3 and H2 atmospheres (Fig. 2(a)), whereas it is increased by the target molecules at 30 Hz (Fig. 2(b)). The directions of the impedance changes were the same for both the target molecules. On the other hand, at 350 Hz (Fig. 2(c)), Z re decreases in the CH3COCH3 atmosphere, although it stays constant in the H2 atmosphere. This clearly demonstrates that CH3COCH3 can be selectively detected against H2 by impedance measurement with an appropriate measurement frequency. Discus...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.