BackgroundThe covered self-expandable metallic stents (SEMS) have been used to manage benign tracheobronchial stenosis, especially the complex post-tuberculosis (TB) tracheobronchial stenosis (PTTS) with cartilage destruction or malacia. This procedure could lead to stent-related tracheoesophageal fistula (TEF).Case presentationA 21-year-old woman, who had one covered Y-shaped SEMS inserted to manage complex PTTS 2 years ago, presented with dyspnea and frequent coughing on drinking water. The bronchoscopy confirmed extensive granulation tissue hyperplasia and a TEF on the upper edge of the covered SEMS. The covered SEMS was removed in three steps, and another fully covered Y-shape SEMS (Microtech Co., Ltd., Nanjing, China) was inserted to restore patency in the tracheobronchial tree and occlude the TEF orifice. Recombinant bovine basic fibroblast growth factor (rbFGF) (6,000 IU/time) was sprayed into and around the fistula through the V-System single-use cannula via the flexible bronchoscope every other week. The patient showed sustained clinical and radiographic improvement, and the TEF healed.ConclusionWe presented a three-step bronchoscopic approach to managing a stent-related TEF in a patient with complex PTTS. Subsequently, regular bronchoscopic debridement of granulation tissue developing on the upper edge of SEMS is necessary to maintain the stent patency and reduce the risk of recurrent stent-related TEF. A fully covered SEMS associated with the local administration of rbFGF seems to offer an alternative simplified one-stage procedure for the temporary management of TEF combined with complex PTTS in non-surgical candidates.
BackgroundSelf-expanding metallic stent (SEMS) is a palliative therapy for patients with malignant central airway obstruction (CAO) or tracheoesophageal fistula (TEF). Despite this, many patients experience death shortly after SEMS placement.AimsWe aimed to investigate the effect of SEMS on the palliative treatment between malignant CAO and malignant TEF patients and investigate the associated prognostic factors of the 3-month survival.MethodsWe performed a single-center, retrospective study of malignant CAO or TEF patients receiving SEMS placement. Clinical data were collected using the standardized data abstraction forms. Data were analyzed using SPSS 22.0. A two-sided P-value <0.05 was statistically significant.Results106 malignant patients (82 CAO and 24 TEF) receiving SEMS placement were included. The body mass index (BMI), hemoglobin levels, and albumin levels in the malignant TEF group were lower than in the malignant CAO group (all P < 0.05). The procalcitonin levels, C-reactive protein levels, and the proportion of inflammatory lesions were higher in the malignant TEF group than in the malignant CAO group (all P < 0.05). The proportion of symptomatic improvement after the SEMS placement was 97.6% in the malignant CAO group, whereas 50.0% in the malignant TEF group, with a significant difference (P = 0.000). Three months after SEMS placement, the survival rate at was 67.0%, significantly lower in the malignant TEF group than in the malignant CAO group (45.8% vs. 73.2%, P = 0.013). Multivariate analysis revealed that BMI [odds ratio (OR) = 1.841, 95% certificated interval (CI) (1.155-2.935), P = 0.010] and neutrophil percentage [OR = 0.936, 95% CI (0.883–0.993), P = 0.027] were the independent risk factors for patients who survived three months after SEMS placement.ConclusionsWe observed symptom improvement in malignant CAO and TEF patients after SEMS placement. The survival rate in malignant TEF patients after SEMS placement was low, probably due to aspiration pneumonitis and malnutrition. Therefore, we recommend more aggressive treatment modalities in patients with malignant TEF, such as strong antibiotics, nutrition support, and strategic ventilation. More studies are needed to investigate the prognostic factors in patients with malignant airway disorders receiving SEMS placement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.