Urinary exosomes, secreted into urine from renal epithelial cells, are known to contain many types of renal functional membrane proteins. Here, we studied whether renal ischemia-reperfusion (I/R) affects urinary exosomal aquaporin-1 (AQP1) excretion in rats subjected to renal I/R and patients who underwent renal transplantation. Immunoblotting studies demonstrated reduction of the urinary exosomal AQP1 level even at 6 h after renal I/R, and the level continued to be low over 96 h after I/R. Renal AQP1 mRNA and protein analyses revealed that the decreased excretion of urinary exosomal AQP1 is associated with renal AQP1 protein retention in the early phase and with a decreased expression level of renal AQP1 in the later phase of renal I/R injury. Decreased abundance of urinary exosomal AQP1 in a recipient patient was also observed at 48 h after renal allograft transplantation. No significant decrease in urinary exosomal AQP1 was observed in a rat model of nephropathy or in patients with proteinuria. Our studies suggest that the renal AQP1 expression level is possibly controlled by its urinary exosomal excretion and indicate that urinary exosomal AQP1 is a novel urinary biomarker for renal I/R injury.
A 40-year-old woman was admitted with complaints of headache, palpitation and diaphore sis. She had undergone right hemithyroidectomy 12 years previously. Histological reexamination of the operative specimen revealed a medullary thyroid carcinoma. Abdominal ultrasonography, CT scan and angiography showed bilateral adrenal tumors. Serum catecholamine levels in both adrenal veins were high. Based on these data, bilateral adrenalectomy was performed. Histological examination confirmed the diagnosis of pheochromocytomas. After operation, serum calcitonin and urinary noradrenaline levels were still high. Further examination by 131I-metaiodobenzylguanidine (MIBG) scintigraphy is planned. (Internal Medicine 31: 798-802, 1992)
SummaryThe purpose of this study was to evaluate the effect of an iterative reconstruction method (IR) on shape reproducibility in three-dimensional (3D) computed tomography images. We used an IR (sinogram-affirmed iterative reconstruction: SAFIRE) implemented in a 64-channel multi slice computed tomography system (Siemens, SOMATOM Definition AS). We scanned a simulated vessel phantom with 180-HU vessel contrast at various radiation doses and reconstructed axial images of filtered back projection (FBP) and SAFIRE. Then we reconstructed multi-planar reconstruction (MPR) and volume rendering (VR) images from the axial images. Roundness was evaluated from MPR images and vessel surface roughness was evaluated from pixel value profiles of a vessel in VR images and visual evaluation by radiological technologists. In comparison on equivalent dose, the roundness and roughness were improved with increase of SAFIRE strength level. However, in comparison on equivalent noise (standard deviation: SD) of axial images, SAFIRE strength levels of 2 to 5 were significantly inferior to FBP (p<0.05). SAFIRE strength of 1 with a dose reduction of 19% maintained the shape reproducibility in all evaluations. Therefore, it would be not appropriate to use the SD of axial image as index for the dose reduction rate determination of 3D-CT images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.