The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in AS-TROSAT, the first Indian Space Observatory. The UVIT instrument has two 375 mm telescopes: one for the far-ultraviolet (FUV) channel (1300-1800Å), and the other for the near-ultraviolet (NUV) channel (2000-3000Å) and the visible (VIS) channel (3200-5500Å). UVIT is primarily designed for simultaneous imaging in the two ultraviolet channels with spatial resolution better than 1.8 , along with provision for slit-less spectroscopy in the NUV and FUV channels.The results of in-orbit calibrations of UVIT are presented in this paper.
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is reported. The performance in orbit is also compared with estimates made from the calibrations done on the ground. The sensitivity is found to be within ~15% of the estimates, and the spatial resolution in the NUV is found to exceed significantly the design value of 1.8" and it is marginally better in the FUV. Images obtained from UVIT are presented to illustrate the details revealed by the high spatial resolution. The potential of multi-band observations in the ultraviolet with high spatial resolution is illustrated by some results.
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 arcmin. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 -1.7 arcsec in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. At the end of the PV phase, the instrument calibration is almost complete and the remaining calibrations will be completed by September 2016. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
In the quest for the formation and evolution of galaxy clusters, Rakos and coworkers introduced a spectrophotometric method using the modified Strömgren photometry. But with the considerable debate toward the project's abilities, we re-introduce the system by testing for the repeatability of the modified Strömgren colors and compare them with the Strömgren colors, and check for the reproducibility of the ages and metallicities (using the Principle Component Analysis (PCA) technique and the GALEV models) for the six common galaxies in all the three A779 data sets. As a result, a fair agreement between two filter systems was found to produce similar colors (with the precision of 0.09 mag in (uz-vz), 0.02 mag in (bz-yz), and 0.03 mag in (vz-vz)) and the generated ages and metallicities are also similar (with the uncertainty of 0.36 Gyr and 0.04 dex from the PCA and 0.44 Gyr and 0.2 dex using the GALEV models). We infer that the technique is able to relieve the age-metallicity degeneracy by separating the age effects from the metallicity effects, but still unable to completely break. We further extend this paper to re-study the evolution of galaxies in the low mass, dynamically poor A779 cluster, (as it was not elaborately analyzed by Rakos and co-workers in their previous work) by correlating the luminosity (mass), density, radial distance with the estimated age, metallicity, and the star formation history. Our results distinctly show the bimodality of the young, low-mass, metal-poor population with the mean age of 6.7 Gyr (± 0.5 Gyr) and the old, high-mass, metal-rich galaxies with the mean age of 9 Gyr (± 0.5 Gyr). The method also observes the color evolution of the blue cluster galaxies to red (Butcher-Oemler phenomenon), and the downsizing phenomenon. Our analysis shows that the modified Strömgren photometry is very well suited for studying low-and intermediate-z clusters, as it is capable of observing deeper with better spatial resolution at spectroscopic
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.