This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. A total of 118 strains were investigated; of these, 97 (82.2%) strains were correctly identified to the species level and 21 (17.8%) strains were not identified; by comparing the results with those of the reference method of API identification systems using a pure culture, it was found that no strain had been misidentified. Among the 21 strains with no identification, 13 (61.9%) strains were nonfermenters. The direct-identification reporting time of VITEK 2 was 3.3 h. Direct testing of susceptibility to 11 antibiotics, i.e., amikacin, cefepime, ceftazidime, ciprofloxacin, gentamicin, imipenem, meropenem, netilmicin, piperacillin, piperacillin-tazobactam, and tobramycin, was also performed by using the broth microdilution (MB) method according to the NCCLS guidelines as a reference. After comparing the MICs of the VITEK 2 system with those obtained by the MB method within ؎twofold dilution, it was determined that the 1,067 organism-antibiotic combinations had an overall correct rate of 97.6% (1,041 combinations). The rates of susceptibility to the 11 antibiotics ranged from 88.7 to 100%, respectively. Only two (0.2%) and four (0.4%) combinations of the susceptibility tests gave very major errors (i.e., reported as sensitive by the VITEK 2 system but shown to be resistant by the MB method) and major errors (i.e., reported as resistant by the VITEK 2 system but shown to be sensitive by the MB method), respectively. The reporting time for the direct testing of susceptibility against the 11 antibiotics for 97 blood culture isolates by the VITEK 2 system ranged from 3.3 to 17.5 h. Compared with conventional methods that require 1 or 2 days, this method can make same-day reporting possible and thus permit better patient management.The detection of bloodstream infections is one of the most important tasks performed by the clinical microbiology laboratory. Rapid bacterial identification and susceptibility testing not only improve patient therapy and outcome, but also reduce costs (1,17,18). Both automated blood culture systems and automated systems for identification and susceptibility testing of bacteria have been on the market for a number of years (8). The VITEK 2 system (BioMérieux) is a new automated bacterial identification and susceptibility testing system that uses fluorescence-based technology. Previous studies showed that this system could give reliable identification and susceptibility results with pure bacterial cultures (5, 6, 10). This study explores the possibility of combining these systems to achieve rapid identification and susceptibility testing by direct inoculation from positive blood cultures. MATERIALS AND ME...
A total of 281 strains of miscellaneous members of the family Enterobacteriaceae, Pseudomonas aeruginosa, and other gram-negative bacteria were evaluated by use of identification tests with the VITEK 2 system (bioMérieux) and an API identification system (bioMérieux). A total of 237 (95%) strains were correctly identified to the species level. Only six (2.1%) strains were misidentified, and eight (2.8%) strains were not identified. Among 14 strains with discrepant identifications, 8 (57.1%) strains were nonfermenters. The susceptibilities of 228 strains to 11 antibiotics including amikacin, netilmicin, tobramycin, gentamicin, ciprofloxacin, imipenem, meropenem, ceftazidime, cefepime, piperacillin, and piperacillin in combination with tazobactam were tested with the VITEK 2 ASTNo. 12 card and by the broth microdilution (MB) method, according to NCCLS guidelines, as a reference. For the 2,508 organism-antibiotic combinations, the rates at which duplicate MICs correlated within ؎1 dilution ranged from 84.2 to 95.6%. Only 13 (0.5%) and 10 (0.4%) of the susceptibility tests gave major errors (resistant with the VITEK 2 system but sensitive by the MB method) and very major errors (sensitive with the VITEK 2 system but resistant by the MB method), respectively. Both VITEK 2 ID-GNB (an identification system) and VITEK 2 AST-No. 12 (a susceptibility testing system) card systems gave rapid, reliable, and highly reproducible results.Automated bacterial identification and susceptibility testing systems have been developed and commercialized for more than two decades, but only a few of them are available on the market (1, 2). The VITEK 2 system (bioMérieux), which uses a new fluorescence-based technology, was evaluated for the identification and susceptibility testing of gram-negative clinical isolates.Clinical isolates were collected from 1996 to 1999 in the Prince of Wales Hospital, Hong Kong, People's Republic of China, and were stored in cryotubes at Ϫ70°C. The stock culture strains were then subcultured onto MacConkey agar plates to check their purity. The turbidity of the bacterial suspensions was adjusted with a densitometer to match that of a McFarland 0.5 standard in 0.45% sterile sodium chloride solution. The time interval between suspension preparation and card filling was less than 30 min to avoid changes in turbidity. Afterward, the VITEK 2 ID-GNB cards, AST-No. 12 cards, and bacterial suspension were manually loaded into the VITEK 2 system. Each test card was automatically filled with a bacterial suspension, sealed, and incubated for 3 h. During this period, the cards were read by kinetic fluorescence measurement every 15 min. The VITEK 2 system software first analyzed the data and then reported the results automatically.A total of 281 strains of miscellaneous members of the family Enterobacteriaceae (n ϭ 173), Pseudomonas aeruginosa (n ϭ 23), and other gram-negative bacteria (n ϭ 85) were tested with the VITEK 2 ID-GNB cards. The reference identification was obtained with the API 20E system (bioMérieux) (3).Th...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.