Abstract. Submersible pressure transducers have been utilized for collecting water level data since the early 1960s. Together with a digital data logger, it is a convenient way to record water level fluctuations for long-term monitoring. Despite the wide use of pressure transducers for water level monitoring, little has been reported regarding their accuracy and performance under field conditions. The effects of temperature fluctuations on the output of vented pressure transducers were considered in this study. The pressure transducers were tested under both laboratory and field conditions. The results of this study indicate that temperature fluctuation has a strong effect on the transducer output. Rapid changes in temperature introduce noise and fluctuations in the water level readings under a constant hydraulic head while the absolute temperature is also related to sensor errors. The former is attributed to venting and the latter is attributed to temperature compensation effects in the strain gauges. Individual pressure transducers responded differently to the thermal fluctuations in the same testing environment. In the field of surface hydrology, especially when monitoring fine-scale water level fluctuations, ignoring or failing to compensate for the temperature effect can introduce considerable error into pressure transducer readings. It is recommended that a performance test for the pressure transducer is conducted before field deployment.
Abstract. Accurate measurement of the amount and timing of surface runoff at multiple scales is needed to understand fundamental hydrological processes. At the plot scale (i.e., length scales on the order of 1-10 m) current methods for direct measurement of runoff either store the water in a collection vessel, which is not conducive to long-term monitoring studies, or utilize expensive installations such as largescale tipping buckets or flume/weir systems. We developed an alternative low-cost, robust and reliable instrument to measure runoff that we call the "Upwelling Bernoulli Tube" (UBeTube). The UBeTube instrument is a pipe with a slot machined in its side that is installed vertically at the base of a runoff collection system. The flow rate through the slot is inferred by measuring the water height within the pipe. The geometry of the slot can be modified to suit the range of flow rates expected for a given site; we demonstrate a slot geometry that is capable of measuring flow rates across more than 3 orders of magnitude (up to 300 L min −1 ) while requiring only 30 cm of hydraulic head. System accuracy is dependent on both the geometry of the slot and the accuracy of the water level measurements. Using a pressure sensor with ±7 mm accuracy, the mean theoretical error for the demonstrated slot geometry was ∼ 17 % (ranging from errors of more than 50 % at low flow rates to less than 2 % at high flow rates), while the observed error during validation was 1-25 %. A simple correction factor reduced this mean error to 0-14 %, and further reductions in error could be achieved through the use of taller, narrower slot dimensions (which requires greater head gradients to drive flow) or through more accurate water level measurements. The UBeTube device has been successfully employed in a long-term rainfall-runoff study, demonstrating the ability of the instrument to measure surface runoff across a range of flows and conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.