A: This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6×10 9 particles/cm 2 . In our work, three types of silicon photodetectors from Hamamatsu with areas 3×3 mm 2 and different subpixel sizes of 25×25 µm 2 , 50×50 µm 2 , and 75×75 µm 2 were used. The changes in the SiPM dark count rate (DCR) spectrum before and after irradiation in temperatures in the range of 20 • C to −65 • C are presented. The influence of the DCR changes on the energy resolution of the 662 keV gamma line from the 137 Cs for a non-irradiated GAGG:Ce (1%) scintillator is investigated. The time period of usability of the SiPM detector irradiated by protons in cosmic space was estimated.
The measurement in 2014 of the nonproportionality of each decay component in CsI:Tl found opposite slopes of the fast and tail nonproportionality curves above about 10 keV. Somewhat earlier experiments on nonproportionality and resolution versus shaping time in NaI:Tl and CsI:Tl showed that proportionality and intrinsic resolution could be improved by including the slower “tail” component of the scintillation pulse. The observed opposing nonproportionality trends of fast and tail components constitute a basis for improvement of scintillator nonproportionality if they are added in a suitable linear combination. We examine whether combining the rise and decay components pulse by pulse with an algorithm of optimized proportions may also improve energy resolution. The premise is that a scintillation pulse carries more information about the particle stopping event than is conveyed in a simple measurement of the pulse height. In this work, we measured pulse shapes of individual gamma events in CsI:Tl and other scintillators using an eMorpho multichannel analyzer as a digital oscilloscope. Decomposition of every scintillation pulse into a rise and three exponential decay components allowed us to represent the pulse height spectrum as a linear combination of them. We found that energy resolution of CsI:Tl can be altered and improved through changing the weight of decay components in the linear combination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.