Peri-operative SARS-CoV-2 infection increases postoperative mortality. The aim of this study was to determine the optimal duration of planned delay before surgery in patients who have had SARS-CoV-2 infection. This international, multicentre, prospective cohort study included patients undergoing elective or emergency surgery during October 2020. Surgical patients with pre-operative SARS-CoV-2 infection were compared with those without previous SARS-CoV-2 infection. The primary outcome measure was 30-day postoperative mortality. Logistic regression models were used to calculate adjusted 30-day mortality rates stratified by time from diagnosis of SARS-CoV-2 infection to surgery. Among 140,231 patients (116 countries), 3127 patients (2.2%) had a pre-operative SARS-CoV-2 diagnosis. Adjusted 30-day mortality in patients without SARS-CoV-2 infection was 1.5% (95%CI 1.4-1.5). In patients with a pre-operative SARS-CoV-2 diagnosis, mortality was increased in patients having surgery within 0-2 weeks, 3-4 weeks and 5-6 weeks of the diagnosis (odds ratio (95%CI) 4.1 (3.3-4.8), 3.9 (2.6-5.1) and 3.6 (2.0-5.2), respectively). Surgery performed ≥ 7 weeks after SARS-CoV-2 diagnosis was associated with a similar mortality risk to baseline (odds ratio (95%CI) 1.5 (0.9-2.1)). After a ≥ 7 week delay in undertaking surgery following SARS-CoV-2 infection, patients with ongoing symptoms had a higher mortality than patients whose symptoms had resolved or who had been asymptomatic (6.0% (95%CI 3.2-8.7) vs. 2.4% (95%CI 1.4-3.4) vs. 1.3% (95%CI 0.6-2.0), respectively). Where possible, surgery should be delayed for at least 7 weeks following SARS-CoV-2 infection. Patients with ongoing symptoms ≥ 7 weeks from diagnosis may benefit from further delay.
SARS-CoV-2 has been associated with an increased rate of venous thromboembolism in critically ill patients. Since surgical patients are already at higher risk of venous thromboembolism than general populations, this study aimed to determine if patients with peri-operative or prior SARS-CoV-2 were at further increased risk of venous thromboembolism. We conducted a planned sub-study and analysis from an international, multicentre, prospective cohort study of elective and emergency patients undergoing surgery during October 2020. Patients from all surgical specialties were included. The primary outcome measure was venous thromboembolism (pulmonary embolism or deep vein thrombosis) within 30 days of surgery. SARS-CoV-2 diagnosis was defined as peri-operative (7 days before to 30 days after surgery); recent (1-6 weeks before surgery); previous (≥7 weeks before surgery); or none. Information on prophylaxis regimens or pre-operative anti-coagulation for baseline comorbidities was not available. Postoperative venous thromboembolism rate was 0.5% (666/123,591) in patients without SARS-CoV-2; 2.2% (50/2317) in patients with peri-operative SARS-CoV-2; 1.6% (15/953) in patients with recent SARS-CoV-2; and 1.0% (11/1148) in patients with previous SARS-CoV-2. After adjustment for confounding factors, patients with peri-operative (adjusted odds ratio 1.5 (95%CI 1.1-2.0)) and recent SARS-CoV-2 (1.9 (95%CI 1.2-3.3)) remained at higher risk of venous thromboembolism, with a borderline finding in previous SARS-CoV-2 (1.7 (95%CI 0.9-3.0)). Overall, venous thromboembolism was independently associated with 30-day mortality ). In patients with SARS-CoV-2, mortality without venous thromboembolism was 7.4% (319/4342) and with venous thromboembolism was 40.8% (31/76). Patients undergoing surgery with peri-operative or recent SARS-CoV-2 appear to be at increased risk of postoperative venous thromboembolism compared with patients with no history of SARS-CoV-2 infection. Optimal venous thromboembolism prophylaxis and treatment are unknown in this cohort of patients, and these data should be interpreted accordingly.
Background Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally. Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income countries globally, and identified factors associated with mortality. MethodsWe did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis, exomphalos, anorectal malformation, and Hirschsprung's disease. Recruitment was of consecutive patients for a minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause, in-hospital mortality for all conditions combined and each condition individually, stratified by country income status. We did a complete case analysis. FindingsWe included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal malformation, and 517 with Hirschsprung's disease) from 264 hospitals (89 in high-income countries, 166 in middleincome countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58•0%) were male. Median gestational age at birth was 38 weeks (IQR 36-39) and median bodyweight at presentation was 2•8 kg (2•3-3•3). Mortality among all patients was 37 (39•8%) of 93 in low-income countries, 583 (20•4%) of 2860 in middle-income countries, and 50 (5•6%) of 896 in high-income countries (p<0•0001 between all country income groups). Gastroschisis had the greatest difference in mortality between country income strata (nine [90•0%] of ten in lowincome countries, 97 [31•9%] of 304 in middle-income countries, and two [1•4%] of 139 in high-income countries; p≤0•0001 between all country income groups). Factors significantly associated with higher mortality for all patients combined included country income status (low-income vs high-income countries, risk ratio 2•78 [95% CI 1•88-4•11], p<0•0001; middle-income vs high-income countries, 2•11 [1•59-2•79], p<0•0001), sepsis at presentation (1•20 [1•04-1•40], p=0•016), higher American Society of Anesthesiologists (ASA) score at primary intervention (ASA 4-5 vs ASA 1-2, 1•82 [1•40-2•35], p<0•0001; ASA 3 vs ASA 1-2, 1•58, [1•30-1•92], p<0•0001]), surgical safety checklist not used (1•39 [1•02-1•90], p=0•035), and ventilation or parenteral nutrition unavailable when needed (ventilation 1•96, [1•4...
Rationale and Objective: Three-dimensional (3D) printing allows innovative solutions for personal protective equipment, particularly in times of crisis. Our goal was to generate an N95-alternative 3D-printed respirator that passed Occupational Safety and Health Administration (OSHA)-certified quantitative fit testing during the COVID-19 pandemic. Materials and Methods: 3D printed prototypes for N95 solutions were created based on the design of commercial N95 respirators. Computed tomography imaging was performed on an anthropomorphic head phantom wearing a commercially available N95 respirator and these facial contour data was used in mask prototyping. Prototypes were generated using rigid and flexible polymers. According to OSHA standards, prototypes underwent subsequent quantitative respirator fit testing on volunteers who passed fit tests on commercial N95 respirators. Results: A total of 10 prototypes were 3D printed using both rigid (n = 5 designs) and flexible materials (n = 5 designs), Prototypes generated with rigid printing materials (n = 5 designs) did not pass quantitative respirator fit testing. Three of the five prototypes with flexible materials failed quantitative fit testing. The final two prototypes designs passed OSHA-certified quantitative fit tests with an overall mean fit factor of 138 (passing is over 100). Conclusion: Through rapid prototyping, 3D printed N95 alternative masks were designed with topographical facial computed tomography data to create mask facial contour and passed OSHA-certified quantitative respiratory testing when flexible polymer was used. This mask design may provide an alternative to disposable N95 respirators in case of pandemic-related shortages. Furthermore, this approach may allow customization for those that would otherwise fail fit testing on standard commercial respirators.
Purpose Many commonly used mask designs are secured by elastic straps looping around the posterior auricular region. This constant pressure and friction against the skin may contribute to increased wearer pain, irritation, and discomfort. The purpose of this work is to report a modified 3D printed mask extender to alleviate discomfort and increase mask wearability by relieving posterior auricular pressure from isolation masks. Methods Our institutional review board designated this project as non-human research and exempt. As part of resourcing 3D printing laboratories along with individual 3D printers to provide resources to healthcare workers, mask extenders were printed to relieve posterior auricular pressure from individuals wearing isolation masks. The authors modifed an existing mask extender, increasing its length with accompanying peripheral rungs for isolation mask securement. 3D printing was performed with Ultimaker S5 (Ultimaker B.V.; Geldermalsen, Netherlands) and CR-10 (Creality3D; Shenzhen, China) 3D printers using polylactic acid filaments. The author’s modified extended mask extenders were printed and freely delivered to healthcare workers (physicians, nurses, technologists, and other personnel) at the authors’ institution. Results The final mask extender design was printed with the two 3D printers with a maximum 7 straps printed simultaneously on each 3D printer. Mean print times ranges from 105 min for the Ultimaker S5 printer and 150 min for the CR-10. Four hundred seventy-five mask extenders were delivered to healthcare workers at the authors’ institution, with the demand far exceeding the available supply. Conclusion We offer a modification of a 3D printed mask extender design that decreases discomfort and increases the wearability of isolation mask designs with ear loops thought to relieve posterior auricular skin pressure and ability to control strap tension. The design is simple, produced with inexpensive material (polylactic acid), and have been well-received by healthcare providers at our institution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.