Introduction:
Distal biceps repair is commonly performed using various fixation devices, each having its advantages and drawbacks. All-suture soft anchor (ASSA) is a recent device mitigating some of the issues associated with previous devices.
Materials and Methods:
This retrospective study including 20 patients (21 ruptures) aims to evaluate the safety and functionality of ASSA by modified tension-slide technique. All operations were performed through a single-incision anterior approach using two 2.9 mm anchors. All but 1 were men with a mean age of 50.5 years. The mean duration from injury to surgery was 14 days.
Results:
At a mean follow-up of 11.8 months, compared with contralateral extremity, 18 (86%) of 21 regained full biceps strength with 5/5 flexion-supination power, while 3 displayed 4/5 power. All, except 1, returned to the previous level of function at an average of 24 weeks. As per the modified Mayo Elbow Performance Index, 18 (86%) achieved excellent and 3 (14%) had good results. Complications included lateral antebrachial cutaneous nerve palsy in 12 (resolved in 10), superficial radial nerve palsy in 1 (resolved), and heterotopic ossification in 1. No device-related complications or reruptures were noted.
Conclusion:
Primary repair of distal biceps tendon ruptures through the use of the ASSA is a viable option, which in conjunction with the proposed modification of tension-slide suture fixation technique yields clinically objective and functional results.
Level of Evidence:
Level IV—therapeutic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.