Method for improving the time resolution of a TOF system * LI Shao-Li( ) 1,2,3;1) HENG Yue-Kun( ) 1,2;2) ZHAO Tian-Chi( ) 4 FU Zai-Wei() 5 LIU Shu-Lin( ) 2 QIAN Sen( ) 2 LIU Shu-Dong() 2 CHEN Xiao-Hui( ) 1,2,3 JIA Ru( ) 6 HUANG Guo-Rui( ) 7 LEI Xiang-Cui( ) 1,2,3
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESIII). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.