The surface Electromyography (sEMG) signal contains information about movement intention generated by the human brain, and it is the most intuitive and common solution to control robots, orthotics, prosthetics and rehabilitation equipment. In recent years, gesture decoding based on sEMG signals has received a lot of research attention. In this paper, the effects of muscle fatigue, forearm angle and acquisition time on the accuracy of gesture decoding were researched. Taking 11 static gestures as samples, four specific muscles (i.e., superficial flexor digitorum (SFD), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL) and finger extensor (FE)) were selected to sample sEMG signals. Root Mean Square (RMS), Waveform Length (WL), Zero Crossing (ZC) and Slope Sign Change (SSC) were chosen as signal eigenvalues; Linear Discriminant Analysis (LDA) and Probabilistic Neural Network (PNN) were used to construct classification models, and finally, the decoding accuracies of the classification models were obtained under different influencing elements. The experimental results showed that the decoding accuracy of the classification model decreased by an average of 7%, 10%, and 13% considering muscle fatigue, forearm angle and acquisition time, respectively. Furthermore, the acquisition time had the biggest impact on decoding accuracy, with a maximum reduction of nearly 20%.
The existing Human-Machine Interfaces (HMI) based on gesture recognition using surface electromyography (sEMG) have made significant progress. However, the sEMG has inherent limitations as well as the gesture classification and force estimation have not been effectively combined. There are limitations in applications such as prosthetic control and clinical rehabilitation, etc. In this paper, a grasping gesture and force recognition strategy based on wearable A-mode ultrasound and two-stage cascade model is proposed, which can simultaneously estimate the force while classifying the grasping gesture. This paper experiments five grasping gestures and four force levels (5-50%MVC). The results demonstrate that the performance of the proposed model is significantly better than that of the traditional model both in classification and regression (p<0.001). Additionally, the two-stage cascade regression model (TSCRM) used the Gaussian Process regression model (GPR) with the mean and standard deviation (MSD) feature obtains excellent results, with normalized root-mean-square error (nRMSE) and correlation coefficient (CC) of 0.1049 ± 0.0374 and 0.9461±0.0354, respectively. Besides, the latency of the model meets the requirement of real-time recognition (T<15ms). Therefore, the research outcomes prove the feasibility of the proposed recognition strategy and provide a reference for the field of prosthetic control, etc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.