Frost heaving damage of canal lining in cold and dry areas is one of the important causes of canal leakage. In this paper, based on the bending theory of thin plate, a mechanical model of canal lining under the action of frost heaving force is established and solved. Through parametric and engineering case analysis, the following conclusions are drawn: under the action of frost heaving force, the bending moment, shear force, and internal force of the slope plate show a nonuniform distribution, and the maximum values of bending moment Mx and normal stress σx are close to the bottom third of the slope, which is consistent with the existing research and engineering practice. Compared with the theory of beam, the results of the theory of thin plates show that the internal forces and stresses increase at the free boundary (longitudinal expansion joint). The bending moment Mxy and stress τxy are maximum at the four corners of the plate: although the numerical magnitude is lower than that of Mx, it may cause stress concentration to damage the lining plate and thus cause break. The shear force at the longitudinal expansion joint may lead to fracture of the joint material, which needs to be considered in the design process. Due to the uniform distribution of the frost heaving force on the bottom plate lining, its deflection, internal forces, and stresses also show a uniform distribution. The research results can provide scientific reference for the design and operation and maintenance of water transmission canal lining in cold areas.
The lining of water conveyance canals in cold regions is usually subjected to serious damage, such as spalling, bulging, and fracture, due to the harsh natural environment. The main causes of these types of damage are the normal frost-heaving force and tangential frost-heaving force (adfreeze force) acting on the liner plate. In this study, the adfreeze forces between the foundation soil and liner plate were studied using the direct shear test, considering the effects of the initial water content, test temperature, and compactness. The results show that the increase of the water content, the increase of the temperature, and the decrease of the compactness increased the interfacial peak shear displacement, and they all varied in the range of 0.3–1.6 mm. With the decrease of the initial water content of the soil sample, the increase of the test temperature, and the decrease of the compactness, the peak shear stress decreased significantly with the amplitude between 51 and 87%. The interfacial cohesion decreased significantly with the increase of the initial water content, the increase of the temperature, and the decrease of the compactness. The interfacial friction angle had no apparent variation pattern. At room temperature, the interfacial friction angle decreased significantly with the increase of the water content. When the water content was 30%, the interfacial friction angle was almost lost completely, which can easily lead to the sliding loss of the foundation soil and further damage, such as the instability of the lining.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.