Spinal cord injury (SCI) is associated with a dismal prognosis including severe voluntary motor and sensory deficits in the presence of the current therapies, thus new and efficient treatment strategies are desperately required. Along with several advantages, such as easy accessibility, high-yield, potential of enormous proliferation, menstrual blood-derived mesenchymal stem cells (MenSCs) have been proposed as a promising strategy in regeneration medicine. In this study, the MenSCs were transplanted into incomplete thoracic (T10) spinal cord injury (SCI) rats, all rats were sacrificed at 7, 14, and 28 days after surgery. Based on the results, we found that MenSCs transplantation improved the hind limb motor function. Besides, H&E staining showed that MenSCs treatment markedly reduced cavity formation in the lesion site. Furthermore, treatment by MenSCs showed more MAP2-positive mature neurons, as well as axonal regeneration manifested by NF-200 and less expression of chondroitin sulfate proteoglycans (CSPGs) than the non-treatment in the lesion site. Additionally, immunofluorescence, Western blot, and qRT-PCR methods showed that levels of brain-derived neurotrophic factor (BDNF) were significantly higher in the injured spinal cord after implantation of MenSCs. Results of qRT-PCR indicated that inflammatory factors, including TNF-α and IL-1β were inhibited after MenSCs transplantation. The improved motor function of hind limb and the increased cell body area of motor neurons were suppressed by blocking of the BDNF-TrkB signaling. It was eventually revealed that MenSCs implantation had beneficial therapeutic effects on the rehabilitation of the rat spinal cord hemisection model, mainly by enhancing the expression of BDNF. MenSCs transplantation may provide a novel therapeutic strategy for patients with SCI in the future.
It is of great significance to study the dynamic characteristics of twin ball screw (TBS) feed system to improve the precision of gantry-type dual-driven computer numerical control (CNC) machine tools. In this paper, an equivalent dynamic model of the TBS feed system is established utilizing lumped mass method considering the stiffness of joints. Equivalent axial stiffness of screw-nut joints and bearing joints are both calculated by Hertz contact theory. Furthermore, a friction model is proposed because the friction force of the screw nut affects the stiffness of the joints. Then, the friction parameters are obtained by using the nonlinear system identification method. Meanwhile, a finite element model (FEM) is developed to assess the dynamic characteristics of TBS feed system under the stiffness of joints. Finally, validation experiments are conducted, and the results show that the positions of the nut and the velocities of worktable greatly affect the dynamic characteristics of the TBS feed system. Compared with the theoretical calculation, FEM and experiments indicate that the dynamic modeling proposed in this article can reach a higher accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.