The aim of this study was to investigate the effect and mechanism of chronic intermittent hypoxia (CIH) on cerebral injury using the ischemia-reperfusion rat model. In total, 36 SD rats were divided into three groups: pseudo-surgery group (sham group), ischemia-reperfusion (IR) group (CIR group), and CIH intervention group (CIH group). The IR model was established using the suture-occluded method. CIH intervention was performed starting at 12 weeks prior to the establishment of the IR model for rats in the CIH group. Ultra-microstructure was examined using an electron microscope. Expression of intercellular cell adhesion molecule-1 (ICAM-1) and vascular endothelial growth factor (VEGF) in rat brain tissue was evaluated by immunohistochemical methods and western blot assays. The neurological deficit scores of rats in the CIH group were higher than those in the CIR group (p < 0.05). Using electron microscopy, we observed more severe edema around the capillaries of the rat brain that resulted in more pressure on the vascular wall of the capillaries in the CIH group compared to the CIR group. The expression of ICAM-1 and VEGF in rat brain tissue was rare in the sham group, but was significantly elevated in the CIR group (p < 0.05) and even higher in the CIH group, compared to the CIR group. Hence, the brain injury in ischemia-reperfusion rat models following CIH intervention may be related to the increased expression of ICAM-1 and VEGF.
Abstract:The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors' distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from ±25 µm to ±15 µm and the relative error was not more than 0.011%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.