If hazardous contaminants are suddenly released indoors, quickly identifying the pollutants characteristics, such as the locations and emission rates, of the contaminant sources is critical for developing fast and effective response measures. This study presents a theoretical model for quickly identifying the locations and emission rates of multiple constant sources indoors using a single or limited number of ideal sensors. The model combines a linear programming model with an analytical expression of indoor contaminant dispersion that was presented in our previous study. Before the release of contaminants, only a limited number of time-consuming computational fluid dynamics (CFD) simulations need to be conducted to cover a large number of possible scenarios because of the analytical expression integrated into the model. After the release of contaminants, the model can be solved in real-time. Through case studies of sixteen contaminant release scenarios in a three-dimensional office, the effectiveness of the model was numerically demonstrated and validated. The results revealed that the identification accuracy of the presented model was closely related to the sensor layouts and the total sampling time, rather than the sampling interval.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.