Geomagnetically induced current (GIC) is known to be closely related to the rate of change of local horizontal magnetic field (dBx/dt); and their spectra can give better insight into the relationship. We study the spectral characteristics of GIC measured in Finland and dBx/dt measured 30 km away during the 17 March 2013 intense geomagnetic storm (SymHMin = -132 nT). Two bursts of large GIC (up to 32A) and dBx/dt occurred at ~ 16 UT and 18 UT during the storm main phase, though their values were generally small. For the first time, the Cross Wavelet Transform (XWT) and Wavelet Coherence (WTC) techniques are used to investigate the correlation and phase relationship of GIC and dBx/dt in time-frequency domain. Their WTC correlation is strong (over 0.9) over the entire storm period, indicating dBx/dt is the main factor causing GIC and dBx/dt leading GIC. Their XWT spectra show two enclosed periods (8–42 min and 2–42 min) in the high energy region corresponding to the two bursts of activity in GIC and dBx/dt. Moreover, we use continuous wavelet transform (CWT) and discrete wavelet transform (DWT) to analyze the spectral characteristics of GIC and dBx/dt. It is found that the CWT and DWT spectra of the two are very similar, especially in the low frequency characteristics, without continuous periodicity. Wavelet coefficients become large when GIC and dBx/dT are large; and the third-order coefficient, which corresponds to low-frequency part, best reflects the disturbance of GIC and dBx/dt.
Transmission congestion not only increases the operation risk, but also reduces the operation efficiency of power systems. Applying a quasi-dynamic thermal rating (QDR) to the transmission congestion alarm system can effectively alleviate transmission congestion. In this paper, according to the heat balance equation under the IEEE standard, a calculation method of QDR is proposed based on the threshold of meteorological parameters under 95% confidence level, which is determined by statistical analysis of seven-year meteorological data in Weihai, China. The QDR of transmission lines is calculated at different time scales. A transmission congestion management model based on QDR is established, and the transmission congestion alarm system including conductor temperature judgment is proposed. The case shows that transmission congestion management based on QDR is feasible, which improves the service life and operation flexibility of the power grid in emergencies and avoids power supply shortages caused by unnecessary trip protection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.