BackgroundTo quantify the metabolite changes in hepatic tumors by single-voxel 1H magnetic resonance spectroscopy (MRS) at 3.0 T and explore the application value of 1HMRS in the diagnosis of hepatic benign and malignant lesions.Material/MethodsA total of 45 patients (55 lesions) diagnosed with hepatic lesions by ultrasound and/or computer topography (CT) from November 2006 to March 2007 were included in this study. All patients underwent 3D-dynamic enhanced scan with liver acquisition with acceleration volume acquisition (LAVA) sequence and single-voxel 1HMRS imaging with PRESS (point-resolved spectroscopy) sequence. The metabolite concentrations such as choline (Cho) and lipids (Lip) were measured.ResultsThere was significant difference regarding the occurrence rate of the obvious elevated Cho peaks between benign and malignant tumors (7/27 vs. 21/28, p=0.000). There was statistical significant differences regarding the Cho/Lip ratios in hepatic benign (0.0686±0.0283, 95% CI: 0.0134–0.1245) and malignant (0.1266±0.1124, 95% CI: 0.0937–0.2203) lesions (p<0.05). When compared with the pathological results, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy were 85.7% (24/28), 92.6% (25/27), 92.3% (24/26), 86.2% (25/29), and 89.1% (49/55) respectively for the MRI assessment, and 92.6% (26/28), 88.9% (24/27), 89.7 (26/29), 92.3 (24/26), and 90.9% (50/55) respectively for 1HMRS combined with MRI assessment.ConclusionsSingle Cho peaks or Lip peaks cannot be used for the diagnosis of hepatic benign and malignant lesions. Combined use of 1HMRS and MRI can greatly improve the application value of MRI assessment in the diagnosis of hepatic benign and malignant lesions with a higher sensitivity, negative predictive value, and overall accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.