A passive optical fiber laser heterodyne radiometer prototype with a semiconductor laser near 1.316 μm as the local oscillator was built, parameters of the prototype have been optimized. Using the prototype, the water vapor concentration in the atmospheric column was measured with a spectral resolution of 0.009 cm−1 in late October and early November of 2020, the collection time was approximately 3 min, and the signal-to-noise ratio was better than 120. The water vapor column concentration and profiles were inversed based on the optimal estimation method. Compared with the measurement of the Fourier transform spectrometer (EM27/SUN) which was performed simultaneously, the inversion results deviated by less than 14%, and the variation trend of the water vapor concentration showed good consistency. It is demonstrated that the 1.316 μm optical fiber laser heterodyne radiometer possesses good stability and accuracy in the field measurement of atmospheric water vapor concentration.
A high sensitivity wavelength modulated reinjection off-axis integrated cavity output spectroscopy (WM-RE-OA-ICOS) experimental setup was built at a 2 μm band. On the basis of an off-axis integrated output spectroscopy (OA-ICOS), combined with an optical reinjection (RE) approach to improve signal intensity, and wavelength modulation spectroscopy (WMS) to improve the signal-to-noise ratio (SNR) of the system, the experimental study of trace CO2 with high sensitivity was carried out using the setup. The performance was compared and evaluated, and the results show that: Compared with the OA-ICOS, the wavelength modulated reinjection OA-ICOS enhanced the signal intensity by 6.3 times, and the SNR increased 7.2 times from 179 to 1288. The Allan variance results showed that the detection limit of the system is 0.35 ppm when the average system time is 230 s. The setup was used to measure the indoor CO2 concentration for a long time (22 h), and the measured results were in line with the actual concentration change. The proposed method shows good performance enhancement for the OA-ICOS system in trace gas measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.