This study simulates a multi-pinhole single-photon emission computed tomography (SPECT) system using the Monte Carlo method, and investigates different multi-pinhole designs for quantitative mouse brain imaging. Prior approaches investigating multi-pinhole SPECT were not often optimal, as the number and geometrical arrangement of pinholes were usually chosen empirically. The present study seeks to optimize the number of pinholes for a given pinhole arrangement, and also for the specific application of quantitative neuroreceptor binding in the mouse brain. An analytical Monte Carlo simulation based method was used to generate the projection data for various count levels. A three-dimensional ordered-subsets expectation-maximization algorithm was developed and used to reconstruct the images, incorporating a realistic pinhole model for resolution recovery and noise reduction. Although artefacts arising from overlapping projections could be a major problem in multi-pinhole reconstruction, the cold-rod phantom study showed minimal loss of spatial resolution in multi-pinhole systems, compared to a single-pinhole system with the same pinhole diameter. A quantitative study of neuroreceptor binding sites using a mouse brain phantom and low activity (37 MBq) showed that the multi-pinhole system outperformed the single-pinhole system by maintaining the mean and lowering the variance in the measured uptake ratio. Multi-pinhole collimation can be used to reduce the injected dose and thereby reduce the radiation exposure to the animal. Results also suggest that the nine-pinhole configuration shown in this paper is a good choice for mouse brain imaging.
This paper demonstrates the application of mutual information based coregistration of radionuclide and magnetic resonance imaging (MRI) in an effort to use multimodality imaging for noninvasive localization of stem cells grafted in the infarcted myocardium in rats. Radionuclide imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) inherently has high sensitivity and is suitable for tracking of labeled stem cells, while high-resolution MRI is able to provide detailed anatomical and functional information of myocardium. Thus, coregistration of PET or SPECT images with MRI will map the location and distribution of stem cells on detailed myocardium structures. To validate this coregistration method, SPECT data were simulated by using a Monte Carlo-based projector that modeled the pinhole-imaging physics assuming nonzero diameter and photon penetration at the edge. Translational and rotational errors of the coregistration were examined with respect to various SPECT activities, and they are on average about 0.50 mm and 0.82°, respectively. Only the rotational error is dependent on activity of SPECT data. Stem cells were labeled with 111 Indium oxyquinoline and grafted in the ischemic myocardium of a rat model. Dual-tracer small-animal SPECT images were acquired, which allowed simultaneous detection of 111 In-labeled stem cells and of [ 99m Tc]sestamibi to assess myocardial perfusion deficit. The same animals were subjected to cardiac MRI. A mutual-information-based coregistration method was then applied to the SPECT and MRIs. By coregistration, the 111 In signal from labeled cells was mapped into the akinetic region identified on cine MRIs; the regional perfusion deficit on the SPECT images also coincided with the akinetic region on the MR image.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.