SummaryBackgroundPregnant women with type 1 diabetes are a high-risk population who are recommended to strive for optimal glucose control, but neonatal outcomes attributed to maternal hyperglycaemia remain suboptimal. Our aim was to examine the effectiveness of continuous glucose monitoring (CGM) on maternal glucose control and obstetric and neonatal health outcomes.MethodsIn this multicentre, open-label, randomised controlled trial, we recruited women aged 18–40 years with type 1 diabetes for a minimum of 12 months who were receiving intensive insulin therapy. Participants were pregnant (≤13 weeks and 6 days' gestation) or planning pregnancy from 31 hospitals in Canada, England, Scotland, Spain, Italy, Ireland, and the USA. We ran two trials in parallel for pregnant participants and for participants planning pregnancy. In both trials, participants were randomly assigned to either CGM in addition to capillary glucose monitoring or capillary glucose monitoring alone. Randomisation was stratified by insulin delivery (pump or injections) and baseline glycated haemoglobin (HbA1c). The primary outcome was change in HbA1c from randomisation to 34 weeks' gestation in pregnant women and to 24 weeks or conception in women planning pregnancy, and was assessed in all randomised participants with baseline assessments. Secondary outcomes included obstetric and neonatal health outcomes, assessed with all available data without imputation. This trial is registered with ClinicalTrials.gov, number NCT01788527.FindingsBetween March 25, 2013, and March 22, 2016, we randomly assigned 325 women (215 pregnant, 110 planning pregnancy) to capillary glucose monitoring with CGM (108 pregnant and 53 planning pregnancy) or without (107 pregnant and 57 planning pregnancy). We found a small difference in HbA1c in pregnant women using CGM (mean difference −0·19%; 95% CI −0·34 to −0·03; p=0·0207). Pregnant CGM users spent more time in target (68% vs 61%; p=0·0034) and less time hyperglycaemic (27% vs 32%; p=0·0279) than did pregnant control participants, with comparable severe hypoglycaemia episodes (18 CGM and 21 control) and time spent hypoglycaemic (3% vs 4%; p=0·10). Neonatal health outcomes were significantly improved, with lower incidence of large for gestational age (odds ratio 0·51, 95% CI 0·28 to 0·90; p=0·0210), fewer neonatal intensive care admissions lasting more than 24 h (0·48; 0·26 to 0·86; p=0·0157), fewer incidences of neonatal hypoglycaemia (0·45; 0·22 to 0·89; p=0·0250), and 1-day shorter length of hospital stay (p=0·0091). We found no apparent benefit of CGM in women planning pregnancy. Adverse events occurred in 51 (48%) of CGM participants and 43 (40%) of control participants in the pregnancy trial, and in 12 (27%) of CGM participants and 21 (37%) of control participants in the planning pregnancy trial. Serious adverse events occurred in 13 (6%) participants in the pregnancy trial (eight [7%] CGM, five [5%] control) and in three (3%) participants in the planning pregnancy trial (two [4%] CGM and one [2%] control). The most...
Desensitized patients are at high risk of developing acute antibody-mediated rejection (AMR). In most cases, the rejection episodes are mild and respond to a short course of plasmapheresis (PP) / low-dose IVIg treatment. However, a subset of patients experience severe AMR associated with sudden onset oliguria. We previously described the utility of emergent splenectomy in rescuing allografts in patients with this type of severe AMR. However, not all patients are good candidates for splenectomy. Here we present a single case in which eculizumab, a complement protein C5 antibody that inhibits the formation of the membrane attack complex (MAC), was used combined with PP/IVIg to salvage a kidney undergoing severe AMR. We show a marked decrease in C5b-C9 (MAC) complex deposition in the kidney after the administration of eculizumab.
BACKGROUNDIn patients with type 1 diabetes who are not pregnant, closed-loop (automated) insulin delivery can provide better glycemic control than sensor-augmented pump therapy, but data are lacking on the efficacy, safety, and feasibility of closed-loop therapy during pregnancy. METHODSWe performed an open-label, randomized, crossover study comparing overnight closed-loop therapy with sensor-augmented pump therapy, followed by a continuation phase in which the closed-loop system was used day and night. Sixteen pregnant women with type 1 diabetes completed 4 weeks of closed-loop pump therapy (intervention) and sensor-augmented pump therapy (control) in random order. During the continuation phase, 14 of the participants used the closed-loop system day and night until delivery. The primary outcome was the percentage of time that overnight glucose levels were within the target range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]). RESULTSThe percentage of time that overnight glucose levels were in the target range was higher during closed-loop therapy than during control therapy (74.7% vs. 59.5%; absolute difference, 15.2 percentage points; 95% confidence interval, 6.1 to 24.2; P = 0.002). The overnight mean glucose level was lower during closed-loop therapy than during control therapy (119 vs. 133 mg per deciliter [6.6 vs. 7.4 mmol per liter], P = 0.009). There were no significant differences between closed-loop and control therapy in the percentage of time in which glucose levels were below the target range (1.3% and 1.9%, respectively; P = 0.28), in insulin doses, or in adverseevent rates. During the continuation phase (up to 14.6 additional weeks, including antenatal hospitalizations, labor, and delivery), glucose levels were in the target range 68.7% of the time; the mean glucose level was 126 mg per deciliter (7.0 mmol per liter). No episodes of severe hypoglycemia requiring third-party assistance occurred during either phase. CONCLUSIONSOvernight closed-loop therapy resulted in better glucose control than sensor-augmented pump therapy in pregnant women with type 1 diabetes. Women receiving day-and-night closed-loop therapy maintained glycemic control during a high proportion of the time in a period that encompassed antenatal hospital admission, labor, and delivery.
The requirements for potent immunosuppression coupled with the formidable risk of irreversible antibody-mediated rejection (AMR) have thus far limited the expansion of ABO incompatible (ABOi) kidney transplantation. We present a retrospective review of our single-center experience with 60 consecutive ABOi kidney transplants and describe the evolution of our treatment protocol to one that consists only of a brief escalation in immunosuppression without long-term B-cell suppression from splenectomy or anti-CD20. The 1-, 3-, and 5-year graft survival rates for the cohort were 98.3%, 92.9%, and 88.7%, respectively, which is comparable with United Network for Organ Sharing data for compatible live donor transplants. No instances of hyperacute rejection were observed, and no grafts were lost secondary to AMR. In fact, fewer than 15% of the patients experienced a clinical episode of AMR, and rejections were mild. Elimination of B-cell ablative therapies did not result in an increased incidence of AMR. Excellent graft function persists with a current median creatinine clearance of 60 mL/min. The findings of this study and the relatively simple therapeutic regimen used should facilitate widespread application of ABOi kidney transplantation resulting in one of the most rapid escalations in access to organs in the modern era of kidney transplantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.