The effects of temperature on the chiral recognition of cyclic β-amino acid enantiomers on zwitterionic [Chiralpak ZWIX(+) and ZWIX(-)] chiral stationary phases were investigated. Experiments were performed at different mobile phase compositions and under 10°C column temperature increments in the temperature range 10-50°C. Apparent thermodynamic parameters and T(iso) values were calculated from plots of ln k and ln α versus 1/T, respectively. Unusual temperature behavior was observed, especially on the ZWIX(-) column, where the application of MeOH/MeCN (50/50 v/v) containing 25 mM triethylamine and 50 mM formic acid as mobile phase led to nonlinear van't Hoff plots and increasing retention time with increasing temperature. On both columns, both enthalpically and entropically driven separations were observed.
Stereoselective HPLC separations of five sterically constrained monoterpene-based 2-aminocarboxylic acid enantiomers were carried out by using the newly developed zwitterionic chiral stationary phases Chiralpak ZWIX(+)™ and ZWIX(-)™ based on Cinchona alkaloid. In order to optimize the retention and enantioselectivity parameters, the ratio of the different organic solvents in the mobile phase and the nature of the acid and base additives (counter- and co-ions) were systematically varied. The effects of structure variants of the analytes on the resolution were investigated. The elution sequence was determined in all cases and observed to be opposite on ZWIX(+)™ and ZWIX(-)™.
The application of a chiral ligand-exchange column for the direct high-performance liquid chromatographic enantioseparation of unusual β-amino acids with a sodium N-((R)-2-hydroxy-1-phenylethyl)-N-undecylaminoacetate-Cu(II) complex as chiral selector is reported. The investigated amino acids were isoxazoline-fused 2-aminocyclopentanecarboxylic acid analogs. The chromatographic conditions were varied to achieve optimal separation. The effects of temperature were studied at constant mobile phase compositions in the temperature range 5-45°C, and thermodynamic parameters were calculated from plots of lnk or lnα versus 1/T. Δ(ΔH°) ranged from -2.3 to 2.2 kJ/mol, Δ(ΔS°) from -3.0 to 7.8 J mol(-1) K(-1) and -Δ(ΔG°) from 0.1 to 1.7 kJ/mol, and both enthalpy- and entropy-controlled enantioseparations were observed. The latter was advantageous with regard to the shorter retention and greater selectivity at high temperature. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. The sequence of elution of the enantiomers was determined in all cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.