This paper examines the test results of a hollow-core reinforced concrete prestressed end-notched floor slab of formwork formation subjected to uniformly distributed load. The research of the end-notched slab was carrying out in the testing hall of the State Enterprise "State Research Institute of Building Structures" according to the procedure of standard DSTU B B.2.6-7. Vertical uniformly distributed load was applied to the end-notched slab with cross-rails and support fixtures for loading, with hydraulic jacks and pumping station equipped with force meter. The end-notched slab was subjected to step-by-step loading with load steps of 100 kgf/m2. Inspection of the surface of the end-notched slab in the test area, with recording in the register of measurement results of displacements and potential damages was carried out after every loading step. Vertical displacements of the end-notched slab corners were measured with four clock type indicators ICH-10. Vertical displacements of the middle slab span were measured with two deflectometers 6PAO. The middle span deflection of the end-notched slab was calculated considering corner displacements. Based on the results of research, it was established that before applying the load of 800 kg/m2 there were not detected cracks the opening width of which exceeded the limit values. The loss of loadbearing capacity of the end-notched slab was detected after the load of 1280 kgf/m2, which which exceeded the design load by 1.6 times. The end-notched slab collapsed due to loss of shear resistance. According to the test results, it was established that hollow-core reinforced concrete prestressed end-notched floor slab meets the requirements of strength, stiffness and crack resistance.
В статті узагальнено досвід роботи відділу досліджень конструкцій будівель і споруд щодо спірних питань визначення класу і міцності бетону на стиск. Головним показником якості бетону в бетонних і залізобетонних збірних та монолітних конструкціях є клас бетону на стиск, що відповідає величині його характеристичної міцності. Відомі аналітичне і графічне представлення цього показника. Його не однозначне трактування в існуючій нормативній базі на стадіях підбору складу бетону, виготовлення продукції, експлуатації будівель і споруд призводить до конфлікту економічнихінтересів між сторонами: виробник бетону, будівельник, інвестор. Вирішення проблем однозначного трактування результатів руйнівних та неруйнівних методів випробувань міцності бетону можливе лише за умови перегляду і узгодження чинних нормативів. Представлено аналіз та приклади використання нормативної бази визначення міцності і класу бетону, що діє для виробників і споживачів бетону, та визначення міцності і класу бетону безпосередньо в конструкціях. Наведено приклади необґрунтованого оцінювання міцності при використанні неруйнівних механічних і ультразвукових методів та за контрольними зразками через ігнорування нормативних умов. Для експлуатації конструкцій суттєво забезпеченняфактичного класу міцності бетону, що встановлено проектом. Для його достовірного визначення застосовують випробування зразків з вибурених із конструкції бетонних кернів та тарованих ними неруйнівних методів. Проаналізовано на прикладі різні методи оцінки результатів випробування міцності кернів. Однозначності потребує метод визначення результатів випробування – за окремими результатами чи за їх партіями.
У будівництві з монолітного залізобетону актуальна проблема стикування арматури довгомірних конструкцій через обмеженість довжини стрижнів, безвідходності арматури та проблем зі зварюваністю сталей. Розглянуто ризики та дефекти виконання механічних з’єднань арматурних стрижнів за досвідом їх випробування навантаженням на розтяг для оцінки можливості використання таких з’єднань у монолітних залізобетонних конструкціях. Ризики з’єднання стрижнів опресовуванням муфт визначаються порушеннямитехнічних умов на з’єднувальні муфти, підготовки торців стрижнів, обладнання для пресування та умови опресовування муфти. Окрім геометричних обмежень відповідностей стрижням, що стикуються, муфт і обладнання, важливими є властивості самих муфт (безмовність, якісна сталь марок 10, 15, 20, твердість за Брінеллем не більше 150), підготовка торців стрижнів, параметри опресування, під час яких змінюється структура сталі муфти. При опресуванні середини муфти при розтягу з’єднання стрижнів розрив відбувається по ній. При недостатній пластичності матеріалу муфти відбувається її поздовжній розрив. Пропонується для зменшення ризиків та можливих дефектів опресовування муфт імплантувати в Україні стандарти ISO 5835, забезпечувати відповідну кваліфікацію персоналу, надавати особливу увагу марці і твердості сталі муфт, забезпечувати надійну систему якості робіт.
The paper summarizes the experience of the Department of Buildings and Facilities Structures Research in determining the compressive strength and grade of concrete in the structures, which characterize one of the main requirements for ensuring the structures mechanical strength and stability. Their unambiguous interpretation at the stages of concrete composition selection, products manufacture and structures operation leads to a conflict of interests and corruption risks between a concrete producer, a builder and an investor. Two approaches to the concrete strength and grade assessment are considered: the first one reasons from the economic interests of a concrete producer (the possibility of cement saving at a stable well-organized production facility), the second one takes into account the consumer's point of view (design indicators ensuring). The first approach is based on the coefficient of the tested control concrete cubes strength variation declared by the concrete mixture manufacturer. The calculation of the relationship between the average and characteristic compressive resistance of concrete at various coefficients of concrete compressive strength variation and grades showed that this coefficient can significantly change the assessment results. The second approach is based on the use of reference core samples cut directly from the structure, which are tested and interpreted according to established international experience. The difference in strength assessments is shown for the cases with the use of samples tests results selection compared to groups in which the smallest values are removed. Both approaches are analyzed based on the experience of determining the concrete compressive strength grade using the core samples from the entire floor slab in the existing structure and from some its areas; the results were far from straightforward and not consistent with the project. It is necessary to clearly define the areas of application of norms and standards that, firstly, serve the technology and the production market of concrete and concrete and reinforced concrete products, and secondly, ensure obtaining the actual characteristics of existing products, structures and facilities and their conformity to the project. It is advisable, especially for the structures of the higher levels of responsibility and in some controversial matters, to verify the results obtained with the first approach application to the concrete mix test specimens by testing core samples cut from the structures.
Розглянуто результати експериментальних досліджень роботи енергозберігаючої фасадної вентильованої системи Hilti з прихованим кріпленням плит опорядження природного каменю на каркасі з алюмінієвих елементів за допомогою аграфів. Зразок фрагмента фасадної системи розмірами 4×2 м випробували на стенді в горизонтальному положенні на комплексну дію власної ваги, обледеніння та вітру від розрахункових навантажень експлуатаційних і граничних, позитивних і негативних, в рядовій і кутовій зонах будівлі. Наведені розрахунки навантажень, випробувальне обладнання, схеми випробувань та схеми розміщення вимірювальних приладів. Визначено фізико-механічні характеристики природного каменю плит опорядження. Опорядження випробуваного зразка складали 4 плити розмірами 2035×890×30 мм, масою по 122,5 кг. Визначено величини деформацій опорядження та представлено їх вичерпний аналіз. Руйнівне навантаження в площині плит становило 46,6 кН, що відповідає висоті будівлі 27 м. Характер руйнування зразка – деформація аграфів із вертикальним переміщенням та з розривом з’єднання направляючого аграфного профілю з несучим. Хімічні анкери плит опорядження витримали без пошкодження на вирив вітрове від’ємне навантаження 0,652 кН та на зріз вертикальне навантаження 1,664 кН. Випробуваннями зразка фрагменту фасадної системи встановлено, що система витримала всі передбачені види навантажень експлуатаційних і граничних від власної ваги, двостороннього зледеніння облицювання, вітрового навантаження позитивного і негативного на рядових і кутових ділянках. Під час проектування, монтажу та експлуатації цієї фасадної системи слід враховувати її вразливості: масивність опорядження, надійність з’єднань несучих і аграфних профілів каркасу та самих аграфів, можливість конструктивного забезпечення від зледеніння горизонтальних проміжків між плитами на рівні поверхів.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.