We describe the rapid, label-free detection of Influenza A viruses using a cantilever transducer modified with a synthetic sialylglycopolymer receptor layer. Surface stresses induced by viruses binding to the receptor layer were used as the analytical signal. The synthetic sialylglycopolymer receptor layer can be used in nanoscale strain-gauge cantilever transducers for highly sensitive virus detection. Strain-gage transducers using such sensor layers exhibit long lifetimes, high sensitivities, and possible regeneration. Nanomechanical cantilever systems using optical detectors were used for the surface stress measurements. We demonstrated the positive, label-free detection of Influenza A at concentrations below 10(6) viruses per ml. In contrast to hemagglutination assays, cantilever sensors are label free, in situ, and rapid (less than 30 min), and they require minimal or nearly no sample preparation.
We describe rapid, label-free detection of Influenza A viruses using the first radial mode of oscillations of lead zirconate titanate (PZT) piezoelectric discs with a 2 mm radius and 100 µm thickness fabricated from a piezoelectric membrane. The discs are modified with a synthetic sialylglycopolymer receptor layer, and the coated discs are inserted in a flowing virus suspension. Label-free detection of the virus is achieved by monitoring the disc radial mode resonance frequency shift. Piezo transducers with sialylglycopolymer sensor layers exhibited a long lifetime, a high sensitivity and the possibility of regeneration. We demonstrate positive, label-free detection of Influenza A viruses at concentrations below 10
5
virus particles per millilitre. We show that label-free, selective, sensitive detection of influenza viruses by home appliances is possible in principle.
Experiments from flight- and ground-based model systems suggest that unexpected alterations of the human lymphoblastoid cell line Jurkat, as well as effects on cell growth, metabolism, and apoptosis, can occur in altered gravity conditions. Using a desktop random positioning machine (RPM), we investigated the effects of simulated microgravity on Jurkat cells and their multidrug-resistant subline, Jurkat/A4 cells. The viability of Jurkat/A4 cells decreased after simulated microgravity in contrast with the Jurkat cells. At the same time, the viability between the experimental Jurkat cells and control Jurkat cells was not significantly different. Of note, Jurkat cells appeared as less susceptible to apoptosis than their multidrug-resistant clone Jurkat/A4 cells, whereas cell-cycle analysis showed that the percentage of Jurkat/A4 cells in the S-phase was increased after 72 and 96 h of RPM-simulated microgravity relative to their static counterparts. The differences in Jurkat cells at all phases between static and simulated microgravity were not significant. The surface expression of the intercellular adhesion molecule 3 (ICAM-3)—also known as cluster of differentiation (CD)50—protein was changed for Jurkat/A4 cells following exposure to the RPM. Changes in cell morphology were observed in the Jurkat/A4 cells after 96 h of RPM-simulated microgravity. Thus, we concluded that Jurkat/A4 cells are more sensitive to RPM-simulated microgravity as compared with the parental Jurkat cell line. We also suggest that intercellular adhesion molecule 3 may be an important adhesion molecule involved in the induction of leukocyte apoptosis. The Jurkat/A4 cells with an acquired multidrug resistance phenotype could be a useful model for studying the effects of simulated microgravity and testing anticancer drugs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.