The investigation presents the development of highly sensitive and selective multibiosensor based on different immobilized enzymes as bioselective elements and the matrix of ion-selective field effect transistors as transducers. To develop bioselective elements of multibiosensor, such enzymes as acetylcholinesterase, butyrylcholin esterase, urease, glucose oxidase, and three-enzyme system (invertase, mutarotase, glucose oxidase) were used. The bioselective elements obtained were shown to demonstrate high sensitivity to corresponding substrates in direct enzymatic analysis, which lasted 10 min. Dynamic range of substrate determination (0.1 mM-1.5-10 mM) was shown to depend on an enzymatic system and differ specifically in the upper detection limit. The dependence of multibiosensor response on pH, ionic strength, and buffer capacity was investigated; optimal conditions for simultaneous operation of all bioselective elements of the multibiosensor were selected; the data on cross-influence of substrates for all the enzymes used were obtained. The developed multi-analyzer was shown to demonstrate sufficient signal reproducibility.
Анотація. Розроблено вимірювальний стенд для дослідження основних характеристик датчиків кута повороту з частотним типом вихідного сигналу з високою точністю. Досягнення високої чутливості і точності кутового переміщення механічних частин вимірювального стенда в процесі вимірювання частотно-кутової характеристики досліджуваного датчика реалізовано використанням елементів годинникового механізму (редуктора) з великим передаточним числом. Наводяться результати експериментальних досліджень датчика кута повороту на поверхневих акустичних хвилях (ПАХ) за допомогою запропонованого стенда.Ключеві слова: датчик кута повороту, поверхневі акустичні хвилі, вимірювальний стенд MEASURING STAND FOR ANGLE TURN GAUGE INVESTIGATION ON THE SURFACE ACOUSTIC WAVE Ya. I. Lepikh, P. O. Snigur, A. O. KarpenkoAbstract. The measuring stand for the turn angle gauges with the frequency kind output signal basic characteristic investigation with high accuracy is developed. The achievement measuring stand mechanical parts high sensitivity and accuracy moving during measuring the investigated gauge angle-АКУСТОЕЛЕКТРОННІ СЕНСОРИ ACOUSTOELECTRONIC SENSORS
Abstract. L-arginine conductometric biosensors were developed on the basis of arginase and urease cross-linked by glutaraldehyde in a single bioselective membrane and modified with clinoptilolite. The clinoptilolite intrinsic properties helpful for conductometric detection of L-arginine were investigated using three approaches to the creation of zeolite-containing enzymatic membranes. The developed biosensors were compared with the L-arginine biosensor, not modified with clinoptilolite, for the sensitivity, linear and dynamic range, detection limit, response time, operational and storage stability in L-arginine analysis. It was shown that the incorporation of ammonium-selective zeolite to the bioselective membrane of L-arginine biosensor allows increasing the biosensor sensitivity when applying all proposed approaches to the formation of zeolite-containing biomembranes. In addition, excellent values of both detection limit and linear range (1.0×10-5 M and 0.01-6 mM, respectively) were achieved for the biosensor based on arginase, urease and zeolite distributed in a single bioselective layer. The clinoptilolite-based biosensors for L-arginine demonstrated short response time, high operational stability (a coefficient of variations reached 0.74%), their lifetime exceeded four months.Keywords: L-arginine; Clinoptilolite; Conductometric biosensor; Arginase; Urease ЗАСТОСУВАННЯ АМОНІЙ-СЕЛЕКТИВНОГО ЦЕОЛІТУ ДЛЯ ПОКРАЩЕННЯ КОНДУКТОМЕТРИЧНОГО ДВОФЕРМЕНТНОГО БІОСЕНСОРА ДЛЯ ВИЗНАЧЕННЯАнотація. Розроблено кондуктометричні біосенсори для визначення L-аргініну на основі аргінази та уреази, іммобілізованих в одній біоселективній мембрані методом поперечного зшивання за допомогою глутарового альдегіду та модифікованій клиноптилолітом. Характерні властивості клиноптилоліту, корисні для кондуктометричного визначення L-аргініну, були до-слідженні за допомогою трьох підходів для створення цеоліт-вмісних ферментних мембран. Розроблені біосенсори порівнювали з біосенсором для визначення L-аргініну, який не був мо-дифікований клиноптилолітом, за такими показниками, як чутливість, лінійний і динамічний діапазон, нижня межа визначення, час відгуку, операційна стабільність і стабільність при збе-ріганні. Показано, що включення амоній-селективного цеоліту до складу біоселективної мемб-рани L-аргінінового біосенсора дозволяє підвищити чутливість біосенсора, застосовуючи всі запропоновані підходи для формування цеоліт-вмісних біомембран. Крім того було отримано чудові значення нижньої межі визначення та лінійного діапазону (1,0×10-5 М та 0,01-6 мМ від-повідно) у біосенсора, у якому аргіназа, уреаза та цеоліт були розподілені в єдиному біоселек-тивному шарі. Біосенсори для визначення L-аргініну на основі клиноптилоліту мали короткий час відгуку, високу операційну стабільність (коефіцієнт варіації досягав 0,74%), а їх стабіль-ність при зберіганні була вища за чотири місяці. Аннотация. Разработаны кондуктометрические биосенсоры для определения L-аргинина на основе аргиназы и уреазы, иммобилизованных в одной биоселективной мембране методом попе...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.