Vascular tone plays a vital role in regulating blood pressure and coronary circulation, and it determines the peripheral vascular resistance. Vascular tone is dually regulated by the perivascular nerves and the cells in the inside lining of blood vessels (endothelial cells). Only a few methods for measuring vascular tone are available. Because of this, determining vascular tone in different arteries of the human body and monitoring tone changes is a vital challenge. This work presents an approach for determining vascular tone in human extremities based on multi-channel bioimpedance measurements. Detailed steps for processing the bioimpedance signals and extracting the main parameters from them have been presented. A graphical interface has been designed and implemented to display the vascular tone type in all channels with the phase of breathing during each cardiac cycle. This study is a key step towards understanding the way vascular tone changes in the extremities and how the nervous system regulates these changes. Future studies based on records of healthy and diseased people will contribute to increasing the possibility of early diagnosis of cardiovascular diseases.
The electrical impedance method of peripheral vein detection is a novel approach, which offers the advantages of not being expensive and the capability of minimizing and reducing the difficulty of achieving intravenous access in many patients, especially pediatric and obese patients. The electrical impedance method of peripheral vein detection is based on the measurement of electrical impedance using the 4-electrode technique by applying a known alternating current of frequency 100 kHz and constant amplitude to a set of current electrodes and measuring the resulting surface potential at two separate electrodes. This paper presents the results of investigations to estimate the efficiency of this method.
The real-time artery diameter waveform assessment during cardio cycle can allow the measurement of beat-to-beat pressure change and the long-term blood pressure monitoring. The aim of this study is to develop a self-calibrated bio-impedance-based sensor, which can provide regular measurement of the blood-pressure-dependence time variable parameters such as the artery diameter waveform and the elasticity. This paper proposes an algorithm based on analytical models which need prior geometrical and physiological patient parameters for more appropriate electrode system selection and hence location to provide accurate blood pressure measurement. As a result of this study, the red cell orientation effect contribution was estimated and removed from the bio-impedance signal obtained from the artery to keep monitoring the diameter waveform correspondence to the change of blood pressure.
The detection of muscle contraction and the estimation of muscle force are essential tasks in robot-assisted rehabilitation systems. The most commonly used method to investigate muscle contraction is surface electromyography (EMG), which, however, shows considerable disadvantages in predicting the muscle force, since unpredictable factors may influence the detected force but not necessarily the EMG data. Electrical impedance myography (EIM) investigates the change in electrical impedance during muscle activities and is another promising technique to investigate muscle functions. This paper introduces the design, development, and evaluation of a device that performs EMG and EIM simultaneously for more robust measurement of muscle conditions subject to artifacts. The device is light, wearable, and wireless and has a modular design, in which the EMG, EIM, micro-controller, and communication modules are stacked and interconnected through connectors. As a result, the EIM module measures the bioimpedance between 20 and 200 Ω with an error of less than 5% at 140 SPS. The settling time during the calibration phase of this module is less than 1000 ms. The EMG module captures the spectrum of the EMG signal between 20–150 Hz at 1 kSPS with an SNR of 67 dB. The micro-controller and communication module builds an ARM-Cortex M3 micro-controller which reads and transfers the captured data every 1 ms over RF (868 Mhz) with a baud rate of 500 kbps to a receptor connected to a PC. Preliminary measurements on a volunteer during leg extension, walking, and sit-to-stand showed the potential of the system to investigate muscle function by combining simultaneous EMG and EIM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.