BackgroundRobotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC), which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display.Materials and methodsNine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries.ResultsIn robot-assisted surgeries where lesion boundaries were not visually detectable, instrumental tactile diagnostics performed using MTEC provided valid identification and localization of lesions. The results of instrumental tactile diagnostics were concordant with the results of intraoperative ultrasound examination. However, in certain cases, for example, thoracoscopy, ultrasound examination is inapplicable, while MTEC-based tactile diagnostics can be efficiently utilized.ConclusionThe study proved that MTEC can be efficiently used in robot-assisted surgery allowing correct localization of visually undetectable lesions and visually undetectable boundaries of pathological changes of tissues.
Background and Aims Small gastric or colorectal tumours can be visually undetectable during laparoscopic surgeries, and available methods still do not provide a 100% localisation rate. Thus, new methods for further improvements in tumour localisation are highly desirable. In this study, we evaluated the usage of the Medical Tactile Endosurgical Complex (MTEC) in gastrointestinal surgery for localisation of tumours. The MTEC provides the possibility of instrumental mechanoreceptoric palpation, which serves as an analogue of conventional manual palpation. Methods Ninety-six elective surgeries were performed, including 48 open surgeries, 43 laparoscopies, and 5 robot-assisted surgeries. The 20 mm version of the MTEC tactile mechanoreceptor was used in open surgeries, and the 10 mm version in laparoscopic and robot-assisted surgeries. Results The mean time of instrumental mechanoreceptoric palpation was 3 minutes 12 seconds for open surgeries, which constituted the early stage of the learning curve, and 3 minutes 34 seconds for laparoscopic surgeries. No side effects or postoperative complications related to instrumental mechanoreceptoric palpation were observed, and this procedure provided data sufficient for tumour localisation in more than 95% of cases. Conclusion Instrumental mechanoreceptoric palpation performed using MTEC is a simple, safe, and reliable method for tumour localisation in gastrointestinal laparoscopic surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.