2016 Fourth International Conference on 3D Vision (3DV) 2016
DOI: 10.1109/3dv.2016.21
|View full text |Cite
|
Sign up to set email alerts
|

3D Data Acquisition and Registration Using Two Opposing Kinects

Abstract: General rightsThis document is made available in accordance with publisher policies. Please cite only the published version using the reference above. AbstractWe present an automatic, open source data acquisition and calibration approach using two opposing RGBD sensors (Kinect V2) and demonstrate its efficacy for dynamic object reconstruction in the context of monitoring for remote lung function assessment. First, the relative pose of the two RGBD sensors is estimated through a calibration stage and rigid tra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(18 citation statements)
references
References 44 publications
1
17
0
Order By: Relevance
“…Soleimani et al [7] used two identical checker patterns on a double-sided board for the calibration of two Kinect V2. Here, the same checker pattern should be placed at the same position on both sides of the flat board.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Soleimani et al [7] used two identical checker patterns on a double-sided board for the calibration of two Kinect V2. Here, the same checker pattern should be placed at the same position on both sides of the flat board.…”
Section: Related Workmentioning
confidence: 99%
“…In this case, however, the overlapped scanned data required for the correspondence-based registration methods may not be sufficient, which makes it difficult to employ the conventional calibration approaches. To solve this problem, a specially designed calibration device such as a spherical object with a rod [6] or a double-sided checker board [7] can be used. In this paper, a novel calibration method without using any calibration-assisting device is proposed.…”
Section: Introductionmentioning
confidence: 99%
“…dual-Kinect 3-D data acquisition and registration system [27] reconstructs an almost complete 3-D model of a subject, performing the routine PFT in a sitting position, at full frame rate (30fps). Deploying only two Kinect sensors, (a) minimises the temporal and spatial alignment error, (b) reduces the system setup and calibration effort, (c) keeps system costs low, and (d) minimises the overall operation space.…”
Section: A Reconstructing the 3-d Trunk Modelmentioning
confidence: 99%
“…The average error range across 3 boxes at 3 different placements was 0.21− 0.84 cm. The synchronisation and registration methodology, and registration accuracy, is comprehensively reported in [27] and the source code is publicly available. 1…”
Section: A Reconstructing the 3-d Trunk Modelmentioning
confidence: 99%
See 1 more Smart Citation