2008
DOI: 10.1016/j.healun.2007.11.458
|View full text |Cite
|
Sign up to set email alerts
|

446: Successful Subzero Non-Freezing Preservation of Rat Lungs with Supercooling Technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
3
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
2
3
0
Order By: Relevance
“…All the lungs were reperfused successfully in 80 min. Thus, consistent with previous reports [12][13][14][15][16][17], our isolated rat lung perfusion model remained stable throughout the observation period. Airway resistance Airway resistance in the control group increased and was significantly higher than that in the sham group (P < 0.001 at 80 min after reperfusion).…”
Section: Physiological Parameterssupporting
confidence: 91%
See 1 more Smart Citation
“…All the lungs were reperfused successfully in 80 min. Thus, consistent with previous reports [12][13][14][15][16][17], our isolated rat lung perfusion model remained stable throughout the observation period. Airway resistance Airway resistance in the control group increased and was significantly higher than that in the sham group (P < 0.001 at 80 min after reperfusion).…”
Section: Physiological Parameterssupporting
confidence: 91%
“…Isolated rat lung perfusion (Model 829; Hugo-Sachs Elektronik-Harvard Apparatus) was performed as previously reported [12][13][14][15][16][17]. Rats were anesthetized with an intraperitoneal injection of sodium pentobarbital (50 mg/kg), intubated after tracheotomy, and ventilated with ambient air at positive pressure.…”
Section: Isolated Rat Lung Perfusion Modelmentioning
confidence: 99%
“…There have been several reported studies to date that are similar to the present one on organ preservation in a subzero environment with the application of magnetic fields or voltage (8,9). In the report of Okamoto et al (9), 3000 V was applied in a preservation of a rat lung in a j2-C environment, and the preservation state 60 min after perfusion was reported to be better than with conventional lung preservation at 4-C. In a report by Monzen et al (8), a heart and liver were preserved for 24 hr and a kidney for 72 hr at j4-C with an application of 100 V and 500 V, respectively.…”
Section: Discussionsupporting
confidence: 64%
“…Several organ preservation experiments at subzero temperatures have been reported using cryoprotectants such as polyethylene glycol, 2,3-butanediol, or antifreeze protein (5Y7). On the other hand, other groups have reported subzero organ preservation using a special supercooling refrigerator (8,9). However, the functional advantage of heart preservation in these refrigerators has not been reported.…”
mentioning
confidence: 99%
“…for transplantation from less than 6 h to 21 h [19], [20,21]. Okamoto et al show that preservation of a lung in a supercooled state at À2 C, has substantial benefits over the preservation at 4 C [22]. Lungs stored using a method of lung preservation in which electric fields are facilitate supercooling, show better organ function after preservation at À2 C than conventional storage at 4 C. A recent paper has shown that liver can be transplanted after four days of preservation at À6 C with perfusion supercooling [23].…”
Section: Methodsmentioning
confidence: 99%