2015
DOI: 10.1016/j.acra.2015.08.026
|View full text |Cite
|
Sign up to set email alerts
|

70-kVp High-pitch Computed Tomography Pulmonary Angiography with 40 mL Contrast Agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
28
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 31 publications
(31 citation statements)
references
References 32 publications
2
28
1
Order By: Relevance
“…In contrast to the above-mentioned studies (7,12), in our study scan time was not only reduced by increasing pitch, but also by the reduction of rotation time down to 0.25 second. This allowed for a further scan time reduction and resulted in a further reduction of radiation dose.…”
Section: Discussioncontrasting
confidence: 99%
See 1 more Smart Citation
“…In contrast to the above-mentioned studies (7,12), in our study scan time was not only reduced by increasing pitch, but also by the reduction of rotation time down to 0.25 second. This allowed for a further scan time reduction and resulted in a further reduction of radiation dose.…”
Section: Discussioncontrasting
confidence: 99%
“…We think that this accounts mainly to (1) the higher signal in the pulmonary arteries and (2) the reduction of motion artifacts. Li et al (12) assessed image quality, radiation dose, and diagnostic accuracy of 70-kVp high-pitch computed tomography pulmonary angiography (CTPA) using 40 mL contrast agent and sinogram affirmed iterative reconstruction (SAFIRE) compared to 100-kVp CTPA using 60 mL contrast agent and filtered back projection. They found that 70-kVp highpitch CTPA with reduced contrast media and SAFIRE provides comparable image quality and substantial radiation dose savings compared to a routine CTPA protocol (12).…”
Section: Discussionmentioning
confidence: 99%
“…The CM (Accupaque ™ 300, iohexol, 300 mg iodine/ml; GE Healthcare, Munich, Germany) was injected using a power injector (Medrad® Stellant® Injector; Bayer Vital GmbH, Leverkusen, Germany) with a flow rate of 3 ml s 21 in all patients. CM injection was followed by a saline flush (40 ml, 3 ml s 21 ). The classical bolus trigger technique (CareBolus; Siemens Healthcare GmbH) (80 kVp) in the pulmonary trunk (PT) with a threshold of 130 HU was used to trigger the examinations.…”
Section: Scanning Protocolsmentioning
confidence: 99%
“…for CTA, 6,11,18,21 chest CT, 22 paediatric CT 23 and cranial CT. 24 These studies also showed feasibility, diagnostic image quality and a potential for reduction of radiation dose and CM. Up to date, only two studies have reported the results for dual-source 70-kVp CTPA.…”
Section: Imaging Characteristicsmentioning
confidence: 99%
See 1 more Smart Citation