2012
DOI: 10.1103/physrevlett.109.185101
|View full text |Cite
|
Sign up to set email alerts
|

95 GHz Gyrotron with Ferroelectric Cathode

Abstract: Ferroelectric cathodes were reported as a feasible electron source for microwave tubes. However, due to the surface plasma emission characterizing this cathode, operation of millimeter wave tubes based on it remains questionable. Nevertheless, the interest in compact high power sources of millimeter waves and specifically 95 GHz is continually growing. In this experiment, a ferroelectric cathode is used as an electron source for a gyrotron with the output frequency extended up to 95 GHz. Power above a 5 kW pea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…The gyrotron output pulse duration is 15 µs [9]. The output mode of the gyrotron is TE02 [10]. The gyrotron output is coupled to a mode converter that converts the radiation first from TE02 to TE01 circular modes, and then to TE10 rectangular mode, coupled into a standard WR10 waveguide.…”
Section: Optimal Load Resistancementioning
confidence: 99%
“…The gyrotron output pulse duration is 15 µs [9]. The output mode of the gyrotron is TE02 [10]. The gyrotron output is coupled to a mode converter that converts the radiation first from TE02 to TE01 circular modes, and then to TE10 rectangular mode, coupled into a standard WR10 waveguide.…”
Section: Optimal Load Resistancementioning
confidence: 99%
“…The simultaneous coexistence of two instabilities in a REB resulting in formation of squeezed state and beam-plasma instability leads to the complex beam dynamics in the system that may be efficiently analyzed mainly with the help of the numerical methods based on the solving of the self-consistent system of Maxwell equations and motion equations of charged particles. For that reason, the three-dimensional fully electromagnetic selfconsistent CST Particle Studio package, which has worked well in the simulation of different beam instabilities and high-power electron devices, [35][36][37][38][39][40][41][42] is used in our work for the accurate numerical investigations of physical processes in the relativistic two-section vircator model.…”
Section: System Under Studymentioning
confidence: 99%
“…By avoiding the use of a slow wave structure, gyrodevices based on the cyclotron resonance maser (CRM) instability, offer higher output power capability [1]. By operating in high order modes, gyrotrons have demonstrated high power (MW) [2] and terahertz operation [3][4][5][6]. However, they can only operate at discrete frequencies.…”
mentioning
confidence: 99%