2015
DOI: 10.1016/j.aeue.2014.09.009
|View full text |Cite
|
Sign up to set email alerts
|

A 3–5 GHz FSK-UWB transmitter for Wireless Personal Healthcare applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 10 publications
0
12
0
Order By: Relevance
“…As delay cell are highly sensitive to PVT variations, the use of voltage controlled delay line allows the compensation of this variations. Two edge (V j and V k ; j,K ϵ [0.7]) are combined to produce complementary baseband pulses (Vc-i-n and Vc-i-p, i ϵ [1][2][3][4]) to control the transmission gate of different current cells (Fig. 8a).…”
Section: Pulse Generator Designmentioning
confidence: 99%
See 1 more Smart Citation
“…As delay cell are highly sensitive to PVT variations, the use of voltage controlled delay line allows the compensation of this variations. Two edge (V j and V k ; j,K ϵ [0.7]) are combined to produce complementary baseband pulses (Vc-i-n and Vc-i-p, i ϵ [1][2][3][4]) to control the transmission gate of different current cells (Fig. 8a).…”
Section: Pulse Generator Designmentioning
confidence: 99%
“…For such devices, the use of wireless link offers autonomous life for users in their residence, allowing out-of-hospital monitoring of health parameters. Indeed, vital sensing systems are used to detect or even prevent the occurrence of worrying and critical situations by generating messages and alarms on the state of the person [1].…”
Section: Introductionmentioning
confidence: 99%
“…1 shows that the basic sensing unit can collect physiological signals (e. g.: such as electroencephalography (EEG), electrocardiography (ECG), body temperature, blood pressure, etc. ), when individual sensors are attached to the human body [2]. The processing unit processes all the sensed signals, then processes all the data based on the communication protocols [3][4].…”
Section: Introductionmentioning
confidence: 99%
“…Due to current hardware limitations, healthcare application of WSNs are still in the early stages [9]. Such devices require Food and Drug Administration (FDA) approval, which can be challenging and costly due to the requirement that the devices pass a number of safety tests.…”
Section: Introductionmentioning
confidence: 99%
“…: such as EEG, ECG, body temperature, blood pressure, heart beat etc. ), when attached to a human body [9]. The processing unit processes all the sensed signals, then sends out the data based on communication protocols.…”
Section: Introductionmentioning
confidence: 99%