2021
DOI: 10.1109/tpel.2021.3103434
|View full text |Cite
|
Sign up to set email alerts
|

A 380-12V, 1kW, 1MHz Converter Using a Miniaturized Split-Phase, Fractional Turn Planar Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(7 citation statements)
references
References 29 publications
0
7
0
Order By: Relevance
“…The transformer power density is the ratio of output power to transformer volume. The loss percentage of the traditional fractional-turn transformers is 1.07% ~ 1.63% [11,12,14,15,17], while that of the proposed transformer is only 0.62%, which is reduced by 42% ~ 62%. The power density of the traditional fractional-turn transformers is 39.5W/cm 3 ~ 72.7W/cm 3 [11,12,14,15,17], while that of the proposed transformer is as high as 140.9W/cm 3 , which is increased by 94% ~ 260%.…”
Section: Vexperimental Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…The transformer power density is the ratio of output power to transformer volume. The loss percentage of the traditional fractional-turn transformers is 1.07% ~ 1.63% [11,12,14,15,17], while that of the proposed transformer is only 0.62%, which is reduced by 42% ~ 62%. The power density of the traditional fractional-turn transformers is 39.5W/cm 3 ~ 72.7W/cm 3 [11,12,14,15,17], while that of the proposed transformer is as high as 140.9W/cm 3 , which is increased by 94% ~ 260%.…”
Section: Vexperimental Resultsmentioning
confidence: 90%
“…This structure is used for the first time in the application with a wide voltage range, and the equivalent transformer ratio can be changed by configure the rectifier bridge [13]. Further, 1MHz LLC DCX is built based on the fractional-winding structure and achieves a full-load efficiency of 96.8% [14]. In [15], a 750kHz, 600W half-turn structure LLC DCX was developed where Litz wire is used for the primary winding and PCB trace is used for the secondary winding.…”
Section: Introductionmentioning
confidence: 99%
“…However, although the side legs help extend the direction of the magnetic flux, the magnetic reluctances of the side legs will be slightly larger than those of the middle magnetic plates so that the magnetic flux distribution is uneven, and the core utilization is reduced. Therefore, Ranjram et al [17] proposed an integrated scheme with the air gap on the magnetic plates and the side legs, which made the magnetic density distribution more uniform, but increased the number of magnets. It also led to higher costs and fixing problems.…”
Section: Structural Design Of Planar Magnetic Coresmentioning
confidence: 99%
“…To address the matter, several techniques such as matrix transformers, integrated magnetics, fractional turn, flux cancellation, interleaved windings, single and multiphase circuits have been proposed and tested at MHz switching frequency. Numerous studies showed that the power density and the efficiency has improved because of increasing the switching frequency to MHz range [2][3][4][5]. Certainly, the overall power density and efficiency of the converter has increased.…”
Section: Introductionmentioning
confidence: 99%
“…1 and Fig. 2) [2][3][4][5]. As an example, the box volume and the net volume of the magnetics designed in [2] are 14.73 cm 3 and 10.88 cm 3 .…”
Section: Introductionmentioning
confidence: 99%