2013
DOI: 10.1109/tuffc.2013.2595
|View full text |Cite
|
Sign up to set email alerts
|

A beamforming study for implementation of vibro-acoustography with a 1.75-D array transducer

Abstract: Vibro-acoustography (VA) is an ultrasound-based imaging modality that uses radiation force produced by two cofocused ultrasound beams separated by a small frequency difference, Δf, to vibrate tissue at Δf. An acoustic field is created by the object vibration and measured with a nearby hydrophone. This method has recently been implemented on a clinical ultrasound system using one-dimensional (1D) linear array transducers. In this article, we discuss VA beamforming and image formation using a 1.75D array transdu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 38 publications
0
9
0
Order By: Relevance
“…These two beams intersect and generate a low frequency modulated ARF at f = 51.5464 kHz at the focal region. The spatial distribution of ARF by using the described configuration is studied by Urban et al 36 During the scanning, a digitally controlled multiplexer was utilized to translate and steer the active aperture along the azimuthal direction and over the total aperture of the transducer. The probe is moved by a motorized linear axis [not shown in Fig.…”
Section: A Q2d Va/us Systemmentioning
confidence: 99%
See 4 more Smart Citations
“…These two beams intersect and generate a low frequency modulated ARF at f = 51.5464 kHz at the focal region. The spatial distribution of ARF by using the described configuration is studied by Urban et al 36 During the scanning, a digitally controlled multiplexer was utilized to translate and steer the active aperture along the azimuthal direction and over the total aperture of the transducer. The probe is moved by a motorized linear axis [not shown in Fig.…”
Section: A Q2d Va/us Systemmentioning
confidence: 99%
“…The Q2D array US transducer was designed for the operating frequencies between 5 and 8 MHz. Since the ultrasound scanner was capable of simultaneously driving 128 channels, a subset of the 12 × 12 elements were selected to form an "active" VA aperture 36 [ Fig. 1(b)].…”
Section: A Q2d Va/us Systemmentioning
confidence: 99%
See 3 more Smart Citations