2016
DOI: 10.1007/s11581-016-1906-8
|View full text |Cite
|
Sign up to set email alerts
|

A calix[4]arene derivative-doped perchlorate-selective membrane electrodes with/without multi-walled carbon nanotubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 64 publications
0
6
0
Order By: Relevance
“…The selectivity of ISE with ISM towards sulphate, nitrate and chloride is also high (Figure 5), which is especially important for the analysis of mineral water samples. In addition, the nitrate anion is often an interfering anion for many perchlorate-ISEs described in literature [40][41][42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57]. To shed light on the exchange reaction mechanism of perchlorate-ISEs with BBU ionophore, the correlation of selectivity coefficients with equilibrium constants of the {X − @BBU} complex was evaluated (Figure 6).…”
Section: Selectivity Of Perchlorate Sc-isementioning
confidence: 99%
See 2 more Smart Citations
“…The selectivity of ISE with ISM towards sulphate, nitrate and chloride is also high (Figure 5), which is especially important for the analysis of mineral water samples. In addition, the nitrate anion is often an interfering anion for many perchlorate-ISEs described in literature [40][41][42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57]. To shed light on the exchange reaction mechanism of perchlorate-ISEs with BBU ionophore, the correlation of selectivity coefficients with equilibrium constants of the {X − @BBU} complex was evaluated (Figure 6).…”
Section: Selectivity Of Perchlorate Sc-isementioning
confidence: 99%
“…Such ion associates (ion exchangers) are also employed in ion-selective electrodes (ISEs) [30][31][32][33][34][35][36][37][38][39]. Potentiometric determination of perchlorate concentration by ISEs is very popular [39][40][41][42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57] because it enables the determination of the concentration in a broad concentration range (−log [ClO 4 − ] = 1-5) with simple instrumentation. There are also some attempts to enlarge the concentration range by lowering the limit of detection (LOD) for the perchlorate ion using a special methodology [37][38][39] or selective receptors, e.g., calixarenes [54][55][56], macrocyclic ligands and their metal complexes [42][43][44]48,49,53].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It was found to be selectively responsive towards the perchlorate ions in micro molar range with an advantage over response time and lifetime. [124] Billing et al has reported a nano-hybrid based on CNT and Pyrene ring, where both the elements are π-π stacked to each other through aromatic rings. The developed nano-hybrid has detected nitrate ions with limit of detection found to be 8.1 nM.…”
Section: Recognition Of Anionsmentioning
confidence: 99%
“… 7 IC was applied by Sungur and Sangün in a wide variety of complex matrices such as soil, water, milk, fish, vegetables and fruits with LOD values between 0.24 and 0.59 μg/kg. 8 For perchlorate determination, there are methodologies such as IC-tandem mass spectrometry, 9 , 10 liquid chromatography-tandem mass spectrometry, 11 , 12 and the ion selective electrode 13 method also existing in the literature.…”
Section: Introductionmentioning
confidence: 99%