A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results

Abstract: Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However, relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional charge-coupled device (CCD) detector. A number of key design features are discussed including the light source; the scanning tank, turntable and stepper motor control; the diffuser screen onto whi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
123
0
4

Year Published

2005
2005
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 153 publications
(130 citation statements)
references
References 22 publications
3
123
0
4
Order By: Relevance
“…For many radiation deliveries this is not the case as beams impinge on the flask in an axial manner. Several correction techniques to minimize refractive wall artifacts have since been proposed [13,17,24]. One method involves forming subtraction images of post and pre-irradiation optical-CT images of the same gel phantom, to subtract out common artifacts (e.g.…”
Section: Artifacts Due To Reflection and Refractionmentioning
confidence: 99%
“…For many radiation deliveries this is not the case as beams impinge on the flask in an axial manner. Several correction techniques to minimize refractive wall artifacts have since been proposed [13,17,24]. One method involves forming subtraction images of post and pre-irradiation optical-CT images of the same gel phantom, to subtract out common artifacts (e.g.…”
Section: Artifacts Due To Reflection and Refractionmentioning
confidence: 99%
“…228 For MR measurements requiring high accuracy and highspatial resolution, long imaging times ͑several hours͒ may be required to achieve the low uncertainty and high spatial resolution associated with standard dosimeters. An alternative readout technique, optical-CT, 166,203,204,209,227,[231][232][233][234][235] has been proposed for imaging PAG gels; an approach analogous to first-generation x-ray CT. In optical-CT the x-ray source is replaced by a visible laser and the x-ray detector replaced with a light-sensitive photodiode.…”
Section: Vb3 Readout Techniquesmentioning
confidence: 99%
“…Much faster broad-beam and cone-beam configurations have been developed for radiochronic gels and plastics, where the scatter component is much less. 232,237 For these approaches corrections may be necessary for spectral warping 238 and residual scatter. 232,239 …”
Section: Vb3 Readout Techniquesmentioning
confidence: 99%
“…In hardware based approach, the detector array is moved during data acquisition to reduce the non-uniform sensitivity of different detector elements. Then an average response of all the detector pixels is calculated to suppress the ring artifacts [8,9]. But in this approach special hardware arrangement is needed.…”
Section: Introductionmentioning
confidence: 99%