2002
DOI: 10.1063/1.1488678
|View full text |Cite
|
Sign up to set email alerts
|

A combined scanning probe microscope

Abstract: A scanning probe microscope, combining a scanning capacitance microscope with a scanning tunneling microscope (STM) using the same probe and input electronics, has been built. The probe is shielded and its stray capacitance is less than 0.5 fF. As an input stage, a wide-bandwidth current-to-voltage converter has been applied. In the capacitance microscope mode, its phase sensitively measures the current flowing through the probe/sample capacitance. The optimum operating frequency is from 1 to 10 MHz. The achie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…The Scanning Capacitance Microscopes sense the capacitance between a sharp tip and the imaged bare or insulator-coated conducting surface [1][2][3][4][5][6][7]. They have found many applications, such as dopant profiling or pn junction delineation in semiconductors [5,[8][9][10][11][12][13], anal- * E-mail: lanyi@savba.sk (Corresponding author) ysis of laser structures [14] or quantum wells [15,16], or even whole wafer processing [17].…”
Section: Introductionmentioning
confidence: 99%
“…The Scanning Capacitance Microscopes sense the capacitance between a sharp tip and the imaged bare or insulator-coated conducting surface [1][2][3][4][5][6][7]. They have found many applications, such as dopant profiling or pn junction delineation in semiconductors [5,[8][9][10][11][12][13], anal- * E-mail: lanyi@savba.sk (Corresponding author) ysis of laser structures [14] or quantum wells [15,16], or even whole wafer processing [17].…”
Section: Introductionmentioning
confidence: 99%
“…Most capacitance sensors use an optimized version of the RCA video disc capacitance pickup that operates at 915 MHz (21). Other modules which measure capacitance directly using low-frequency bridge techniques have also been demonstrated (23,24). However, they are very slow and suffer severely from problems due to changes of stray capacitances or light induced effects (24,25).…”
Section: Introductionmentioning
confidence: 99%
“…The measurement of the complex impedance between tip and sample and simultaneous STM and SCM measurements have also been demonstrated. 10,11 In AFM experiments, the voltage dependent part of the force between the tip and the sample can be interpreted in terms of capacitance. 12,13 For samples with a tip-potential dependent capacitance it is possible to use a low-frequency ac voltage between tip and sample to modulate the capacitance in order to discriminate the local signal from the stray part.…”
Section: Introductionmentioning
confidence: 99%