2018
DOI: 10.1016/j.snb.2018.05.114
|View full text |Cite
|
Sign up to set email alerts
|

A compact breath acetone analyser based on an ultraviolet light emitting diode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…One of the cheapest and very effective methods to increase the detection limit is by using a gas preconcentration structure [ 29 , 30 ]. In addition, scientists are carrying out research for developing a single gas sensor which could cover the exhaled acetone range [ 31 ] and, crucially, work at room temperature [ 32 , 33 , 34 , 35 ], and includes microwave-based [ 36 , 37 ] and optical-based sensors [ 38 , 39 , 40 ]. That makes the process noninvasive, real-time, and less expensive compared to the traditional medical diagnosis methods.…”
Section: Introductionmentioning
confidence: 99%
“…One of the cheapest and very effective methods to increase the detection limit is by using a gas preconcentration structure [ 29 , 30 ]. In addition, scientists are carrying out research for developing a single gas sensor which could cover the exhaled acetone range [ 31 ] and, crucially, work at room temperature [ 32 , 33 , 34 , 35 ], and includes microwave-based [ 36 , 37 ] and optical-based sensors [ 38 , 39 , 40 ]. That makes the process noninvasive, real-time, and less expensive compared to the traditional medical diagnosis methods.…”
Section: Introductionmentioning
confidence: 99%
“…The result shows high linearity, and the correlation coefficient R 2 is 0.9995. We found that the measurement accuracy has a standard deviation of 0.074 ppm, which is a better value compared with the UV absorption measurement reported by Smeeton [ 30 ] (0.2 ppm). For healthy adults, the concentration of breath acetone is between 0.3 and 1.2 ppm [ 33 ], whereas, for diabetics, it is 1–10 ppm [ 36 ].…”
Section: Discussionmentioning
confidence: 41%
“…However, the system is complicated and expensive. Li et al proposed a compact analysis system for breath acetone using a cheap light-emitting diode that can produce 285 nm of UV light [ 30 ]. They also developed a compact multipath gas cell to enhance the sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Evidence for currently available commercial ketone breathalyzers is lacking. Many studies have assessed the utility of novel sensors in the ketogenic diet [ 25 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 ], but very few have evaluated currently available devices. The BIOSENSE™ device is a breathalyzer with published clinical trial data detailing its efficacy.…”
Section: Current Technologymentioning
confidence: 99%