2018 1st International Conference on Advanced Research in Engineering Sciences (ARES) 2018
DOI: 10.1109/aresx.2018.8723300
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Review of Fault Location/Identification Methods in Distribution Networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…In this respect, eleven types of fault (AG, BG, CG, AB, AC, BC, AB-G, AC-G, BC-G, ABC, ABC-G) and also ten fault resistance in the case of ground short-circuit fault R = 0, 20,50,75,100,125,150,175,200 ), five inception angles • (including 0 • , 45 • , 90 • , 135 • ,180 • ) and nineteen distances of fault from recording point (including 500m, 1km,1.5km, 2km, 2.5km, 3km, 3.5km, 4km, 4.5km, 5km, 5.5km, 6km, 6.5km, 7km, 7.5km, 8km, 8.5km, 9km, 9.5km) are simulated. Figs.…”
Section: Atp/emtp Simulated Fault Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this respect, eleven types of fault (AG, BG, CG, AB, AC, BC, AB-G, AC-G, BC-G, ABC, ABC-G) and also ten fault resistance in the case of ground short-circuit fault R = 0, 20,50,75,100,125,150,175,200 ), five inception angles • (including 0 • , 45 • , 90 • , 135 • ,180 • ) and nineteen distances of fault from recording point (including 500m, 1km,1.5km, 2km, 2.5km, 3km, 3.5km, 4km, 4.5km, 5km, 5.5km, 6km, 6.5km, 7km, 7.5km, 8km, 8.5km, 9km, 9.5km) are simulated. Figs.…”
Section: Atp/emtp Simulated Fault Resultsmentioning
confidence: 99%
“…Ultimately the accuracy of the fault identification techniques is reduced as well. As a result, more accurate fault locating or identifying techniques need to be explored by addressing all the inherent behaviors of the DNs [20], [21]. An advanced signal processing technique called the Stockwell Transform (ST) that combines the advantages of wavelet transform and short-time Fourier Transform (FT) was employed recently to detect and classify faults in distribution grids in [22], but not employed in locating faults and identifying faulty sections in distribution grids.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the transient faults restorations lead to an open circuit fault in the OHL, as the reclosing surges weaken and open the OHL jumper connections between the overhead line poles. The four primary types of short circuit faults-line to ground (LG), line to line (LL), double line to ground (DLG), and three line to ground (LLLG)-are regarded as permanent faults [23].…”
Section: Fault Eventsmentioning
confidence: 99%
“…Protective relays can detect breaker states [1,2], types of electrical faults [3,4], and fault locations [5][6][7] in a few seconds. Different protection functions [8] of relays are available for a variety of applications such as to trip/close breakers [9], to locate electrical faults in power grids or lines [10], and detecting faulted phases [4]. Protective relays have front panels with light-emitted diodes (LEDs) that represent the ground and A, B, and C phase states to identify the types of electrical faults [11].…”
Section: Introductionmentioning
confidence: 99%